Dual PWM Fan Controller and Temperature Monitor for High Availability Systems ADM1029*
Supports Hot Swapping of Fans Cascadable Fault Output Allows Fault Signaling between Multiple ADM1029s Address Pin Allows Up to Eight ADM1029s in A System Small 24-Lead QSOP Package APPLICATIONS Network Servers and Personal Computers Microprocessor-Based Office Equipment High Availability Telecommunications Equipment
FEATURES Software Programmable and Automatic Fan Speed Control Automatic Fan Speed Control Allows Control Independent of CPU Intervention after Initial Setup Control Loop Minimizes Acoustic Noise and Power Consumption Remote and Local Temperature Monitoring Dual Fan Speed Measurement Supports Backup and Redundant Fans
FUNCTIONAL BLOCK DIAGRAM
VCC
SCL SERIAL BUS INTERFACE
ADM1029
ADDRESS POINTER REGISTER SLAVE ADDRESS REGISTER INTERRUPT MASK REGISTERS PRESENT1 FAN 1 STATUS REGISTER INTERRUPT STATUS REGISTERS FAULT1 FAN 1 MIN SPEED REGISTER PWM CONTROLLER FAN 1 ALARM SPEED REGISTER FAN 1 HOT-PLUG SPEED REGISTER LIMIT COMPARATOR
SDA
INT INTERRUPT MASKING CFAULT
DRIVE1
VALUE AND LIMIT REGISTERS
RESET
GPIO2 TACH1 TACH2 PRESENT2 FAN SPEED COUNTER FAN 2 STATUS REGISTER G.P. I/O REGISTER
AIN1/GPIO1 AIN0/GPIO0
FAULT2
FAN 2 MIN SPEED REGISTER ADC REMOTE SENSOR SIGNAL CONDITIONING
D2+/GPIO6 D2-/GPIO5 D1+/GPIO4 D1-/GPIO3
DRIVE2
PWM CONTROLLER
FAN 2 ALARM SPEED REGISTER BANDGAP REFERENCE
ANALOG MUX
FAN 2 HOT-PLUG SPEED REGISTER
TMIN/INSTALL BANDGAP TEMP SENSOR ADD
GND
*Protected by U.S. Patent Numbers 6,255,973 and 6,188,189
REV. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of (c)2009 SCILLC. All rights reserved. patents or other rights of third parties that may result from its January 2009 - Rev. 1use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Publication Order Number: Tel: 781/329-4700 www.analog.com ADM1029/D Fax: 781/326-8703 (c) Analog Devices, Inc., 2001
ADM1029-SPECIFICATIONS1, 2 (T = T
A
MIN
to TMAX, VCC = VMIN to VMAX, unless otherwise noted.)
Max 5.5 3.0 60 3 5 Unit V mA mA A C C C C A A % LSB %/ V ms ms 6 255 % rpm rpm rpm rpm kHz V A V A V V mV 60C TA 100C: VCC = 3.3 V Divisor = 1, Fan Count = 153 Divisor = 2, Fan Count = 153 Divisor = 4, Fan Count = 153 Divisor = 8, Fan Count = 153 Test Conditions/Comments
Parameter POWER SUPPLY Supply Voltage, VCC Supply Current, ICC
Min 3.0
Typ 3.30 1.7 1.5 10 1 1 3 1 90 5.5
Interface Inactive, ADC Active ADC Inactive, DAC Active Shutdown Mode
TEMPERATURE-TO-DIGITAL CONVERTER Internal Sensor Accuracy Resolution External Diode Sensor Accuracy Resolution Remote Sensor Source Current ANALOG-TO-DIGITAL CONVERTER Total Unadjusted Error, TUE Differential Nonlinearity, DNL Power Supply Sensitivity Conversion Time Analog Input or Internal Temperature External Temperature FAN RPM-TO-DIGITAL CONVERTER Accuracy Full-Scale Count FAN 1 and FAN 2 Nominal Input RPM 4
0C TA 100C High Level Low Level Note 3
1 1 1 11.6 185.6
Internal Clock Frequency OPEN-DRAIN DIGITAL OUTPUTS (INT, CFAULT) Output Low Voltage, V OL High Level Output Current, I OH OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA) Output Low Voltage, V OL High Level Output Leakage Current, I OH SERIAL BUS DIGITAL INPUTS (SCL, SDA) Input High Voltage, V IH Input Low Voltage, VIL Hysteresis DIGITAL INPUT LOGIC LEVELS RESET, GPIO1-6, FAULT1/2, TACH1/2, PRESENT1/2 Input High Voltage, V IH Input Low Voltage, VIL DIGITAL INPUT CURRENT Input High Current, I IH Input Low Current, IIL Input Capacitance, CIN SERIAL BUS TIMING Clock Frequency, fSCLK Glitch Immunity, tSW Bus Free Time, tBUF Start Setup Time, tSU:STA Start Hold Time, tHD:STA Stop Condition Setup Time, t SU:STO
5
56.4
8800 4400 2200 1100 60.0
63.6 0.4 1 0.4 1
0.1
IOUT = -6.0 mA, VCC = 3 V VOUT = VCC IOUT = -6.0 mA, VCC = 3 V VOUT = VCC
0.1 2.1
0.8 500
2.1 0.8 -1 +1 20 10 50 4.7 4.7 4 4 100
V V A A pF kHz ns s s s s VIN = VCC VIN = 0
See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1
Rev. 1 | Page 2 of 50 | www.onsemi.com
ADM1029
Parameter SERIAL BUS TIMING (continued) SCL Low Time, tLOW SCL High Time, t HIGH SCL, SDA Rise Time, t R SCL, SDA Fall Time, t F Data Setup Time, t SU:DAT Data Hold Time, tHD:DAT
5
Min 1.3 4
Typ
Max
Unit s s ns ns ns ns
Test Conditions/Comments See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1
50 1000 300
250 300
NOTES 1 All voltages are measured with respect to GND, unless otherwise specified. 2 Typicals are at T A = 25C and represent most likely parametric norm. Shutdown current typ is measured with V CC = 3.3 V. 3 TUE (Total Unadjusted Error) includes Offset, Gain, and Linearity errors of the ADC, multiplexer. 4 The total fan count is based on two pulses per revolution of the fan tachometer output. 5 Timing specifications are tested at logic levels of V IL = 0.8 V for a falling edge and V IH = 2.1 V for a rising edge. Specifications subject to change without notice.
ABSOLUTE MAXIMUM RATINGS*
PIN CONFIGURATION
Positive Supply Voltage (VCC) . . . . . . . . . . . . . . . . . . . . . 6.5 V Voltage on Pins 13-18 . . . . . . . . . . . . -0.3 V to (VCC + 0.3 V) Voltage on Any Other Input or Output Pin . . . . -0.3 V to +6.5 V Input Current at Any Pin . . . . . . . . . . . . . . . . . . . . . . . 5 mA Package Input Current . . . . . . . . . . . . . . . . . . . . . . . 20 mA Maximum Junction Temperature (TJ max) . . . . . . . . . . 150C Storage Temperature Range . . . . . . . . . . . . -65C to +150C Lead Temperature Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . . 215C Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200C ESD Rating All Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 V
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
DRIVE1 FAULT1 TACH1 PRESENT1 SCL SDA GND VCC CFAULT
1 2 3 4 5 6 7 8 9
24 DRIVE2 23 FAULT2 22 TACH2 21 PRESENT2 20 AIN1/GPIO1
ADM1029
TOP VIEW (Not To Scale)
19 AIN0/GPIO0 18 TMIN/INSTALL 17 D2+/GPIO6 16 D2-/GPIO5 15 ADD 14 D1+/GPIO4 13 D2-/GPIO3
INT 10 GPIO2 11 RESET 12
THERMAL CHARACTERISTICS
24-Lead QSOP Package: JA = 105C/W, JC = 39C/W
tR tLOW
SCL
tF
tHD;STA
tHD;STA
tHIGH tHD;DAT tSU;DAT
tSU;STA
tSU;STO
SDA
tBUF
P S
S
P
Figure 1. Diagram for Serial Bus Timing
Rev. 1 | Page 3 of 50 | www.onsemi.com
ADM1029
PIN FUNCTION DESCRIPTIONS
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Mnemonic DRIVE1 FAULT1 TACH1 PRESENT1 SCL SDA GND VCC CFAULT INT GPIO2 RESET D1-/GPIO3 D1+/GPIO4 ADD D2-/GPIO5 D2+/GPIO6 TMIN/INSTALL
Description Open Drain Digital Output. Pulsewidth Modulated (PWM) output to control the speed of Fan 1. Requires 10 k typical pull-up resistor. Open Drain Digital I/O. When used with a fan having a fault output, a Logic 0 input to this pin signals a fault on Fan 1. Also used as a fault output. Open Drain Digital Input. Digital fan tachometer input for Fan 1. Will accept logic signals up to 5 V even when VCC is lower than 5 V. Open Drain Digital Input. A shorting link in the fan connector holds this pin low when Fan 1 is connected. Open Drain Digital Input. Serial Bus Clock. Requires 2.2 k pull-up typical. Digital I/O. Serial Bus bidirectional data. Open-drain output requires 2.2 k pull-up. System Ground Power (3.0 V to 5.5 V). Typically powered from 3.3 V power rail. Bypass with the parallel combination of 10 F (electrolytic or tantalum) and 0.1 F (ceramic) bypass capacitors. Open Drain Digital I/O. Cascade fault input/output used for fault signaling between multiple ADM1029s. Digital Output. Interrupt Request (Open Drain). The output is enabled when Bit 1 of the Configuration Register is set to 0. The default state is enabled. Open Drain Digital I/O. General-purpose logic I/O pin. Open Drain Digital Input. Active low reset input. Analog Input/Open Drain Digital I/O. Connected to cathode of external temperature-sensing diode, or may be reconfigured as a general-purpose logic input/output. Analog Input/Open Drain Digital I/O. Connected to anode of external temperature-sensing diode, or may be reconfigured as a general-purpose logic input/output. Eight-Level Analog Input. Used to set the three LSBs of the serial bus address. Analog Input/Open Drain Digital I/O. Connected to cathode of external temperature-sensing diode, or may be reconfigured as a general-purpose logic input/output. Analog Input/Open Drain Digital I/O. Connected to anode of external temperature-sensing diode, or may be reconfigured as a general-purpose logic input/output. Eight-Level Analog Input. The voltage on this pin defines whether automatic fan speed control is enabled, the minimum temperature at which the fan(s) will turn on in automatic speed control mode, and the number of fans that should be installed. Analog Input/Open Drain Digital I/O. May be configured as a 0 V to 2.5 V analog input or as a general-purpose digital I/O pin. Analog Input/Open Drain Digital I/O. May be configured as a 0 V to 2.5 V analog input or as a general-purpose digital I/O pin. Open Drain Digital Input. A shorting link in the fan connector holds this pin low when Fan 2 is connected. Open Drain Digital Input. Digital fan tachometer input for Fan 2. Will accept logic signals up to 5 V even when VCC is lower than 5 V. Open Drain Digital I/O. When used with a fan having a fault output, a Logic 0 input to this pin signals a fault on Fan 2. Also used as a fault output. Open Drain Digital Output. Pulsewidth Modulated (PWM) output to control the speed of Fan 2. Requires 10 k typical pull-up resistor.
19 20 21 22 23 24
AIN0/GPIO0 AIN1/GPIO1 PRESENT2 TACH2 FAULT2 DRIVE2
Rev. 1 | Page 4 of 50 | www.onsemi.com
Typical Performance Characteristics-ADM1029
15
110 100
REMOTE TEMPERATURE ERROR - C
10 5 DXP TO GND 0 DXP TO VCC(3.3V) -5 READING
90 80 70 60 50 40
-10
30 20
-15
10 0
-20 0 3.3 10 30 LEAKAGE RESISTANCE - M 100
0
10
20
30
40
50
60
70
80
90
100
110
MEASURED TEMPERATURE
TPC 1. Remote Temperature Error vs. PC Board Track Resistance
TPC 4. Pentium(R) III Temperature Measurement vs. ADM1029 Reading
4.5 4.0
REMOTE TEMPERATURE ERROR - C
3.5 3.0 2.5 2.0 1.5 1.0 0.5 0
VIN = 100mV p-p -0.5 -1.0 0 1 4 8 12 16 20 50 100 200 300 400 500 600
REMOTE TEMPERATURE ERROR - C
VIN = 250mV p-p
1 0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11 -12 -13 -14 -15 -16 1.0
2.2
FREQUENCY - MHz
3.3 4.7 10.0 DXP - DXN CAPACITANCE - nF
22.0
47.0
TPC 2. Remote Temperature Error vs. Power Supply Noise Frequency
TPC 5. Remote Temperature Error vs. Capacitance Between D+ and D-
10 9
REMOTE TEMPERATURE ERROR - C
80 70 VCC = 5V
8 7 6 5 4 3 2 1
SUPPLY CURRENT -
VIN = 40mV p-p
A
VIN = 100mV p-p VIN = 60mV p-p
60 50 40 30 20 VCC = 3.3V 10
0 -1
0
0
0.4 0.8 10 50 100 150 200 250 300 350 400 450 500 550 600 FREQUENCY - MHz
0
1
5
10
25
50
75
100
250
500
750 1000
SCLK FREQUENCY - kHz
TPC 3. Remote Temperature Error vs. Common-Mode Noise Frequency
TPC = Typical Performance Characteristics Figure
TPC 6. Standby Current vs. Clock Frequency
Rev. 1 | Page 5 of 50 | www.onsemi.com
ADM1029
13 12
10 9
REMOTE TEMPERATURE ERROR - C
LOCAL TEMPERATURE ERROR - C
11 10 9 8 7 6 5 4 3 2 1 0 -1 0 1 4 8 12 16 20 50 100 200 300 FREQUENCY - MHz 400 500 600 VIN = 30mV p-p VIN = 20mV p-p VIN = 40mV p-p
8 7 6 5 4 3 2 1 0 -1 0 1 4 8 12 16 20
VIN = 250mV p-p
VIN = 100mV p-p
50
100 200 300 400 500 600
FREQUENCY - MHz
TPC 7. Remote Temperature Error vs. Differential-Mode Noise Frequency
TPC 10. Local Sensor Temperature Error vs. Power Supply Noise Frequency
32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 1.0
120 110 100 90
SUPPLY CURRENT - A
TEMPERATURE - C
80 70 60 50 40 30 20 10 0
1.4
1.8
2.2 2.6 3.0 3.4 3.8 SUPPLY VOLTAGE - V
4.2
4.6
0
1
2
3
4 5 6 7 TIME - Seconds
8
9
10
TPC 8. Standby Supply Current vs. Supply Voltage
TPC 11. ADM1029 Response to Thermal Shock
1.80 1.75 1.70 1.65 1.60 1.55 1.50 1.45 1.40 1.35 1.30 1.25 1.20 1.15 1.10 1.05 1.00 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 SUPPLY VOLTAGE - V
0.10 0.00 -0.10 -0.20 -0.30
SUPPLY CURRENT - mA
ERROR - C
-0.40 -0.50 -0.60 -0.70 -0.80 -0.90 -1.00 -1.10 -1.20 0 20 40 60 80 85 100 105 120 TEMPERATURE - C
TPC 9. Supply Current vs. Supply Voltage
TPC 12. Remote Temperature Error
TPC = Typical Performance Characteristics Figure
Rev. 1 | Page 6 of 50 | www.onsemi.com
ADM1029
0.05 0.00 -0.05 -0.10 -0.15
FUNCTIONAL DESCRIPTION
SERIAL BUS INTERFACE
Control of the ADM1029 is carried out via the serial bus. The ADM1029 is connected to this bus as a slave device, under the control of a master device. The ADM1029 has a 7-bit serial bus address. The four MSBs of the address are set to 0101. The three LSBs can be set by the user to give a total of eight different addresses, allowing up to eight ADM1029s to be connected to a single serial bus segment. To minimize device pin count and size, the three LSBs are set using a single pin (ADD, Pin 15). This is an 8-level input whose input voltage is set by a potential divider. The voltage on ADD is sampled immediately after power-up and digitized by the on-chip ADC to determine the value of the 3 LSBs. Since ADD is sampled only at power-up, any changes made while power is on will have no effect.
VCC
ERROR - C
-0.20 -0.25 -0.30 -0.35 -0.40 -0.45 -0.50 -0.55 -0.60 0 20 40 60 80 85 100 TEMPERATURE - C 105 120
TPC 13. Local Temperature Error
PRODUCT DESCRIPTION
R1 ADD R2 GND
The ADM1029 is a versatile fan controller and monitor for use in personal computers, servers, telecommunications equipment, or any high-availability system where reliable control and monitoring of multiple cooling fans is required. Each ADM1029 can control the speed of one or two fans and can measure the speed of fans that have a tachometer output. The ADM1029 can also measure the temperature of one or two external sensing diodes or an internal temperature sensor, allowing fan speed to be adjusted to keep system temperature within acceptable limits. The ADM1029 has FAULT inputs for use with fans that can signal failure conditions, and inputs to detect whether or not fans are connected. The ADM1029 communicates with the host processor over an System Management (SMBus) serial bus. It supports eight different serial bus addresses, so that up to eight devices can be connected to a common bus, controlling up to sixteen fans. This makes software support and hardware design scalable. The ADM1029 has an interrupt output (INT) that allows it to signal fault conditions to the host processor. It also has a separate, cascadable fault output (CFAULT) that allows the ADM1029 to signal a fault condition to other ADM1029s. The ADM1029 has a number of useful features including an automatic fan speed control option implemented in hardware with no software requirement, automatic use of backup fans in the event of fan failure, and supports hot-swapping of failed fans.
ADM1029
Figure 2. Setting the Serial Address
Table I shows resistor values for setting the 3 LSBs of the serial bus address. The same principle is used to set the voltage on Pin 18 (TMIN/INSTALL), which controls the automatic fan speed control function, and also tells the ADM1029 how many fans should be installed, as described later. If several ADM1029s are used in a system, their ADD inputs can tap off a single potential divider, as shown in Figure 3.
VCC ADDRESS XXXX111 1.5k ADD ADDRESS XXXX110 1k ADDRESS XXXX101 1k ADDRESS XXXX100 1k ADDRESS XXXX011 1k ADD ADDRESS XXXX010 1k ADD ADDRESS XXXX001 1.5k ADDRESS XXXX000 GND ADD ADD ADD ADD ADD
ADM1029 #1 ADM1029 #2 ADM1029 #3 ADM1029 #4 ADM1029 #5 ADM1029 #6 ADM1029 #7 ADM1029 #8
Figure 3. Setting Address of up to Eight ADM1029s
Rev. 1 | Page 7 of 50 | www.onsemi.com
ADM1029
Table I. Resistor Ratios for Setting Serial Bus Address
3 MSBs of ADC 111 110 101 100 011 010 001 000
Ideal Ratio R2/(R1 + R2) N/A 0.8125 0.6875 0.5625 0.4375 0.3125 0.1875 N/A
R1 (k ) 0 18 22 12 15 47 82
R2 (k ) 82 47 15 12 22 18 0
Actual R2/(R1 + R2) 1 0.82 0.6812 0.5556 0.4444 0.3188 0.18 0
Error % 0 +0.75 -0.63 -0.69 +0.69 +0.63 -0.75 0
Address 0101111 0101110 0101101 0101100 0101011 0101010 0101001 0101000
The serial bus protocol operates as follows: 1. The master initiates data transfer by establishing a START condition, defined as a high-to-low transition on the serial data line SDA, while the serial clock line SCL remains high. This indicates that an address/data stream will follow. All slave peripherals connected to the serial bus respond to the START condition, and shift in the next eight bits, consisting of a 7-bit address (MSB first) plus an R/W bit, which determines the direction of the data transfer, i.e., whether data will be written to or read from the slave device. The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the Acknowledge Bit. All other devices on the bus now remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is a 0, the master will write to the slave device. If the R/W bit is a 1 the master will read from the slave device. 2. Data is sent over the serial bus in sequences of nine clock pulses, eight bits of data followed by an acknowledge bit from the slave device. Transitions on the data line must
occur during the low period of the clock signal and remain stable during the high period, as a low-to-high transition when the clock is high may be interpreted as a STOP signal. The number of data bytes that can be transmitted over the serial bus in a single READ or WRITE operation is limited only by what the master and slave devices can handle. 3. When all data bytes have been read or written, stop conditions are established. In WRITE mode, the master will pull the data line high during the tenth clock pulse to assert a STOP condition. In READ mode, the master device will override the acknowledge bit by pulling the data line high during the low period before the ninth clock pulse. This is known as No Acknowledge. The master will then take the data line low during the low period before the tenth clock pulse, high during the tenth clock pulse to assert a STOP condition. Any number of bytes of data may be transferred over the serial bus in one operation, but it is not possible to mix read and write in one operation, because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation.
Rev. 1 | Page 8 of 50 | www.onsemi.com
ADM1029
1 SCL 9 1 9
SDA START BY MASTER
0
1
0
1
A2
A1
A0
R/W ACK. BY ADM1029
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1029
FRAME 1 SERIAL BUS ADDRESS BYTE 1 SCL (CONTINUED)
FRAME 2 ADDRESS POINTER REGISTER BYTE 9
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1029 STOP BY MASTER
FRAME 3 DATA BYTE
Figure 4a. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1 SCL 9 1 9
SDA START BY MASTER
0
1
0
1
A2
A1
A0
R/W ACK. BY ADM1029
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1029 STOP BY MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 ADDRESS POINTER REGISTER BYTE
Figure 4b. Writing to the Address Pointer Register Only
1 SCL 9 1 9
SDA START BY MASTER
0
1
0
1
A2
A1
A0
R/W ACK. BY ADM1029
D7
D6
D5
D4
D3
D2
D1
D0 NO ACK. STOP BY BY MASTER MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 DATA BYTE FROM ADM1029
Figure 4c. Reading Data from a Previously Selected Register
Rev. 1 | Page 9 of 50 | www.onsemi.com
ADM1029
In the case of the ADM1029, write operations contain either one or two bytes, and read operations contain one byte, and perform the following functions: To write data to one of the device data registers or read data from it, the Address Pointer Register must be set so that the correct data register is addressed, data can be written into that register or read from it. The first byte of a write operation always contains an address that is stored in the Address Pointer Register. If data is to be written to the device, the write operation contains a second data byte that is written to the register selected by the address pointer register. This is illustrated in Figure 4a. The device address is sent over the bus followed by R/W set to 0. This is followed by two data bytes. The first data byte is the address of the internal data register to be written to, which is stored in the Address Pointer Register. The second data byte is the data to be written to the internal data register. When reading data from a register there are two possibilities: 1. If the ADM1029's Address Pointer Register value is unknown or not the desired value, it is first necessary to set it to the correct value before data can be read from the desired data register. This is done by performing a write to the ADM1029 as before, but only the data byte containing the register address is sent, as data is not to be written to the register. This is shown in Figure 4b. A read operation is then performed consisting of the serial bus address, R/W bit set to 1, followed by the data byte read from the data register. This is shown in Figure 4c. 2. If the Address Pointer Register is known to be already at the desired address, data can be read from the corresponding data register without first writing to the Address Pointer Register, so Figure 4b can be omitted. Note: although it is possible to read a data byte from a data register without first writing to the Address Pointer Register, if the Address Pointer Register is already at the correct value, it is not possible to write data to a register without writing to the Address Pointer Register, because the first data byte of a write is always written to the Address Pointer Register.
ALERT RESPONSE ADDRESS REMOTE TEMPERATURE MEASUREMENT
After sending its slave address, the first device will then clear its INT output. The host can then check if the INT is still low and send the general call again if necessary until all devices asserting INT have responded. The ARA function can be disabled by setting Bit 2 of the Configuration Register (address 01h).
TEMPERATURE MEASUREMENT SYSTEM
LOCAL TEMPERATURE MEASUREMENT
The ADM1029 contains an on-chip bandgap temperature sensor, whose output is digitized by the on-chip ADC. The temperature data is stored in the Local Temp Value Register (address A0h). As both positive and negative temperatures can be measured, the temperature data is stored in two's complement format, as shown in Table II. Theoretically, the temperature sensor and ADC can measure temperatures from -128C to +127C with a resolution of 1C, but temperatures outside the operating temperature range of the device cannot be measured by the internal sensor.
The ADM1029 can measure the temperature of one or two remote diode-connected transistors, connected to Pins 13 and 14 and/or 16 and 17. The data from the temperature measurements is stored in the Remote 1 and Remote 2 Temp Value Registers (addresses A1h and A2h). If two remote temperature measurements are not required, Pins 16 and 17 can be reconfigured as general-purpose logic I/O pins, as explained later. The forward voltage of a diode or diode-connected transistor, operated at a constant current, exhibits a negative temperature coefficient of about -2 mV/C. The absolute value of VBE varies from device to device and individual calibration is required to null this out so, unfortunately, the technique is unsuitable for mass production. The technique used in the ADM1029 is to measure the change in VBE when the device is operated at two different currents. This is given by: VBE = KT/q x ln(N) where: K is Boltzmann's constant q is charge on the carrier T is absolute temperature in Kelvins N is ratio of the two currents Figure 5 shows the input signal conditioning used to measure the output of a remote temperature sensor. This figure shows the external sensor as a substrate transistor, provided for temperature monitoring on some microprocessors, but it could equally well be a discrete transistor. If a discrete transistor is used, the collector will not be grounded, and should be linked to the base. If a PNP transistor is used, the base is connected to the D- input and the emitter to the D+ input. If an NPN transistor is used, the emitter is connected to the D- input and the base to the D+ input.
The ADM1029 has an interrupt (INT) output that is asserted low when a fault condition occurs. Several INT outputs can be wire OR'd to a common interrupt line. When the host processor receives an interrupt request, it would normally need to read the interrupt status register of each device to identify which device had made the interrupt request. However, the ADM1029 supports the optional Alert Response Address function of the SMBus protocol. When the host processor receives an interrupt request it can send a general call address (0001100) over the bus. The device asserting INT will then send its own slave address back to the host processor, so the device asserting INT can be identified immediately. If more than one device is asserting INT, all devices will try to respond with their slave address, but an arbitration process ensures that only the lowest address will be received by the host.
Rev. 1 | Page 10 of 50 | www.onsemi.com
ADM1029
VDD
I
N
I
IBIAS
D+
VOUT+ TO ADC
REMOTE SENSING TRANSISTOR
D- BIAS DIODE LOW-PASS FILTER fC = 65kHz
VOUT-
Figure 5. Signal Conditioning for Remote Diode Temperature Sensors
To prevent ground noise interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but biased above ground by an internal diode at the D- input. If the sensor is used in a noisy environment, a capacitor of value up to 1000 pF may be placed between the D+/D- pins. To measure VBE, the sensor is switched between operating currents of I and N x I. The resulting waveform is passed through a 65 kHz low-pass filter to remove noise, and to a chopper-stabilized amplifier that performs the functions of amplification and rectification of the waveform to produce a dc voltage proportional to VBE. This voltage is measured by the ADC to give a temperature output in 8-bit two's complement format. To further reduce the effects of noise, digital filtering is performed by averaging the results of 16 measurement cycles. An external temperature measurement takes nominally 9.6 ms. The results of external temperature measurements are stored in 8-bit, two's complement format, as illustrated in Table II.
OFFSET REGISTERS
TEMPERATURE LIMITS
The contents of the Local and Remote Temperature Value Registers (addresses A0h to A2h) are compared to the contents of the High and Low Limit Registers at addresses 90h to 92h and 98h to 9Ah. How the ADM1029 responds to overtemperature/ undertemperature conditions depends on the status of the Temperature Fault Action Registers (addresses 40h to 42h). The response of CFAULT, INT, and fan-speed-to-temperature events depends on the setting of these registers, as explained later.
Table II. Temperature Data Format
Temperature -128C -125C -100C -75C -50C -25C 0C +10C +25C +50C +75C +100C +125C +127C
Digital Output 1000 1000 1001 1011 1100 1110 0000 0000 0001 0011 0100 0110 0111 0111 0000 0011 1100 0101 1110 0111 0000 1010 1001 0010 1011 0100 1101 1111
Digital noise and other error sources can cause offset errors in the temperature measurement, particularly on the remote sensors. The ADM1029 offers a way to minimize these effects. The offsets on the three temperature channels can be measured during system characterization and stored as two's complement values in three offset registers at addresses 30h to 32h. The offset values are automatically added to, or subtracted from, the temperature values, depending on whether the two's complement number corresponds to a positive or negative offset. Offset values from -15C to +15C are allowed. The default value in the offset registers is zero, so if no offsets are programmed, the temperature measurements are unaltered.
Rev. 1 | Page 11 of 50 | www.onsemi.com
ADM1029
LAYOUT CONSIDERATIONS Table III. Temperature-Specific Registers
Digital boards can be electrically noisy environments, and care must be taken to protect the analog inputs from noise, particularly when measuring the very small voltages from a remote diode sensor. The following precautions should be taken: 1. Place the ADM1029 as close as possible to the remote sensing diode. Provided that the worst noise sources such as clock generators, data/address buses, and CRTs are avoided, this distance can be 4 to 8 inches. 2. Route the D+ and D- tracks close together, in parallel, with grounded guard tracks on each side. Provide a ground plane under the tracks if possible. 3. Use wide tracks to minimize inductance and reduce noise pickup. Ten mil track minimum width and spacing is recommended.
GND 10MIL 10MIL D+ 10MIL 10MIL D- 10MIL 10MIL GND 10MIL
Address 0x06 0x30 0x31 0x32 0x40 0x41 0x42 0x48 0x49 0x4A 0x80 0x81 0x82 0x88 0x89 0x8A 0x90 0x91 0x92 0x98 0x99 0x9A 0xA0 0xA1 0xA2
Description Temp Devices Installed Local Temp Offset Remote 1 Temp Offset Remote 2 Temp Offset Local Temp Fault Action Remote 1 Temp Fault Action Remote 2 Temp Fault Action Local Temp Cooling Action Remote 1 Temp Cooling Action Remote 2 Temp Cooling Action Local Temp TMIN Remote 1 Temp TMIN Remote 2 Temp TMIN Local Temp TRANGE/THYST Remote 1 Temp TRANGE/THYST Remote 2 Temp TRANGE/THYST Local Temp High Limit Remote 1 Temp High Limit Remote 2 Temp High Limit Local Temp Low Limit Remote 1 Temp Low Limit Remote 2 Temp Low Limit Local Temp Value Remote 1 Temp Value Remote 2 Temp Value
Figure 6. Arrangement of Signal Tracks
4. Try to minimize the number of copper/solder joints, which can cause thermocouple effects. Where copper/solder joints are used, make sure that they are in both the D+ and D- path and at the same temperature. Thermocouple effects should not be a major problem as 1C corresponds to about 240 V, and thermocouple voltages are about 3 V/oC of temperature difference. Unless there are two thermocouples with a big temperature differential between them, thermocouple voltages should be much less than 200 V. 5. Place 0.1 F bypass and 1000 pF input filter capacitors close to the ADM1029. 6. If the distance to the remote sensor is more than 8 inches, the use of twisted pair cable is recommended. This will work up to about 6 to 12 feet. 7. For really long distances (up to 100 feet), use shielded twisted pair such as Belden #8451 microphone cable. Connect the twisted pair to D+ and D- and the shield to GND close to the ADM1029. Leave the remote end of the shield unconnected to avoid ground loops. Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance can affect the measurement. When using long cables, the filter capacitor may be reduced or removed. Cable resistance can also introduce errors. 1 series resistance introduces about 0.5C error.
TEMPERATURE-RELATED REGISTERS
The flowchart in Figure 7 shows how to configure the ADM1029 to measure temperature. It also shows how to configure the ADM1029's behavior for out-of-limit temperature measurements.
FAN INTERFACING
The ADM1029 can be interfaced to many types of fan. It can be used to control the speed of a simple two-wire fan. It can measure the speed of a fan with a tach output, and it can accept a logic input from fans with a FAULT output. By means of a shorting link in the fan connector it can also determine if a fan is present or not and if fans have been hot-swapped. The ADM1029 can control or monitor one or two fans. Bits 0 and 1 of the Fans Supported In System Register (03h) tell the ADM1029 how many fans it should be controlling/monitoring. In the following descriptions "installed" means that the corresponding bit of register 03h is set and the ADM1029 expects to see a fan interfaced to it. It does not necessarily mean that the fan is actually, physically, connected. If a fan is installed, events such as a fault output and hot-swapping of the fan can cause INT and CFAULT to be asserted, unless they are masked for that particular event. If a fan is not installed, but is still physically connected to the ADM1029, these events will be ignored with respect to asserting INT or CFAULT, but will still be reflected in the corresponding Fan Status Register. Setting Bit 0 indicates that Fan 1 is installed and is set to 1 at power-up by default. Setting Bit 1 indicates that Fan 2 is installed and depends on the state of Pin 18 (TMIN/INSTALL) at power-up.
Table III is a list of registers on the ADM1029 that are specific to temperature measurement and control.
Rev. 1 | Page 12 of 50 | www.onsemi.com
ADM1029
DEFAULTS LOCAL = 60 C REMOTE 1 = 70 C REMOTE 2 = 70 C CONFIGURE TEMPERATURE LOW LIMITS LOCAL (REG 0x98) REMOTE 1 (REG 0x99) REMOTE 2 (REG 0x9A) BIT 0 = 1 BIT 1 = 1 BIT 2 = 1 BIT 3 = 0 BIT 3 = 1 BIT 4 = 1 BIT 5 = 1 BIT 6 = 1 BIT 7 7 ASSERT CFAULT ON OVER-TEMPERATURE RUN FAN(S) ALARM SPEED ON OVER-TEMPERATURE ASSERT INT ON OVER-TEMPERATURE ALARM BELOW LOW TEMP LIMIT ALARM ABOVE LOW TEMP LIMIT ASSERT CFAULT WHEN LOW TEMP LIMIT CROSSED RUN FAN ALARM SPEED ON UNDER-TEMPERATURE ASSERT INT ON UNDER-TEMPERATURE LATCHES A TEMPERATURE OUT-OF-LIMIT EVENT 6 5 4 3 2 1 0
DEFAULTS LOCAL = 80 C REMOTE 1 = 100 C REMOTE 2 = 100 C
CONFIGURE TEMPERATURE HIGH LIMITS LOCAL (REG 0x90) REMOTE 1 (REG 0x91) REMOTE 2 (REG 0x92)
IS TEMPERATURE > HIGH LIMIT? CONFIGURE TEMPERATURE FAULT ACTION LOCAL (REG 0x40) REMOTE 1 (REG 0x41) REMOTE 2 (REG 0x42) YES CFAULT IS TEMPERATURE > HIGH LIMIT? YES IS TEMPERATURE > HIGH LIMIT? YES INT DEFAULTS LOCAL = 0 C REMOTE 1 = 0 C REMOTE 2 = 0 C CONFIGURE TEMPERATURE OFFSETS LOCAL (REG 0x30) REMOTE 1 (REG 0x31) REMOTE 2 (REG 0x32) ALARM ABOVE OR BELOW LOW TEMP LIMIT? 0 = ALARM BELOW TEMP LIMIT
CONFIGURE TEMPERATURE COOLING ACTION LOCAL (REG 0x48) REMOTE 1 (REG 0x49) REMOTE 2 (REG 0x4A)
FANS RUN ALARM SPEED
1 = ALARM ABOVE TEMP LIMIT MEASURE TEMPERATURE LOCAL (REG 0xA0) REMOTE 1 (REG 0xA1) REMOTE 2 (REG 0xA2) LOW TEMP LIMIT CROSSED? CFAULT YES
LOW TEMP LIMIT CROSSED?
YES FANS RUN ALARM SPEED LOW TEMP LIMIT CROSSED?
YES INT
AUTOMATIC FAN SPEED CONTROL (SEE TABLE X LATER) BIT 0 = 1 BIT 1 = 1 FAN 1 RUNS AT ALARM SPEED FOR OUT-OF-LIMIT TEMPERATURE EVENTS; OTHERWISE, FAN 1 RUNS AT SPEED DETERMINED BY AUTOMATIC FAN CONTROL. FAN 2 RUNS AT ALARM SPEED FOR OUT-OF-LIMIT TEMPERATURE EVENTS; OTHERWISE, FAN 2 RUNS AT SPEED DETERMINED BY AUTOMATIC FAN CONTROL. X X X X X 1 0
X
Figure 7. Temperature Sensing Flowchart
Rev. 1 | Page 13 of 50 | www.onsemi.com
ADM1029
If two fans are installed, Bit 0 would be 1 by default and Pin 18 would be tied high* to set Bit 1. If only one fan is installed, it would normally be Fan 1 and Pin 18 would be tied low* to clear Bit 1. However, both of these bits can be modified by writing to the register, so it is possible to have Fan 2 installed and not Fan 1, or even have no fans installed.
*Note that Pin 18 also sets TMIN for automatic fan speed control. If this function is used, Pin 18 would be set to some other level according to Table VIII.
After the speed of the first fan has been measured, the speed of the second fan (if installed) will be measured in the same way. The measurement cycle will repeat until monitoring is disabled. The fan speed measurements are stored in the Fan Tach Value registers at addresses 70h and 71h. If both fans are installed, Fan 1 will be measured first. If only one fan is installed, the ADM1029 will still try to measure both fans, starting with Fan 1, but the measurement on the noninstalled fan will time out when the Fan Tach Value count overranges. The fan speed count is given by: Count = f where: f is oscillator frequency in Hz factor 4 is because 4 tach periods are counted factor 60 is to convert minutes to seconds R = fan speed in RPM N is number of tach pulses per revolution The frequency of the oscillator can be adjusted to suit the expected frequency range of the fan tach pulses, which depends on the fan speed and the number of tach pulses produced for each revolution of the fan, which is either 1, 2, or 4. The oscillator frequency is set by Bits 7 and 6 of the Fan Configuration Registers (68h for Fan 1 and 69h for Fan 2).
Table III. Oscillator Frequencies
FAULT INPUTS/OUTPUTS
The ADM1029 can be used with fans that have a fault output which indicates if the fan has stalled or failed. If one or both of the FAULT inputs (Pin 2 or Pin 23) goes low, both INT and CFAULT will be asserted. Events on the fault inputs are also reflected in Bits 2 and 3 of the corresponding Fan Status Registers at addresses 10h and 11h. Bit 2 reflects the inverse state of the FAULT pin (0 if FAULT is high, 1 if FAULT is low), while Bit 3 is latched high if a FAULT input goes low. It must be cleared by writing a zero to it. If the fan(s) being used do not have a FAULT output, the FAULT input(s) on the ADM1029 should be pulled high to VCC. The FAULT pins can also be configured as open-drain outputs by setting Bit 5 of the corresponding Fan Fault Action Register (18h or 19h). If a FAULT pin is configured as an output, it will still function as an input. This means that when a fault input occurs it will be latched low by the fault output, even if the fault input is removed. The fault output can be used to drive a fan failure indicator such as an LED. If the FAULT pin is used as an output, any input to the FAULT pin should also be open-drain. This will avoid the fault input trying to source a high current into the FAULT pin if the fault input goes high while the fault output is low.
FAN PRESENT INPUTS
4
60/R/N
Bit 7 0 0 1 1
CLOCK
Bit 6 0 1 0 1
Oscillator Frequency (Hz) Measurement Disabled 470 940 1880
The fan PRESENT signal is implemented by a shorting link to ground in the fan connector. When the fan is plugged in, the corresponding PRESENT input (Pin 4 or Pin 21) on the ADM1029 is pulled low. If the fan is unplugged, the PRESENT input will be pulled high. INT and CFAULT will be asserted (unless masked) and the event will be reflected in Bits 0 and Bit 1 of the corresponding Fan Status Register. Appearance or disappearance of a PRESENT input signal during normal operation signals to the ADM1029 that a fan has been hot-plugged or unplugged. INT and CFAULT will be asserted (unless masked). When a fan is hot-plugged, Bit 7 of the corresponding Fan Status Register will be set and a Fan Free Wheel Test commences automatically.
FAN SPEED MEASUREMENT
CONFIG REG. BIT 4
FAN 1 TACH
FAN 2 TACH FAN 1 MEASUREMENT PERIOD START OF MONITORING CYCLE FAN 2 MEASUREMENT PERIOD
Figure 8. Fan Speed Measurement
FAN SPEED LIMITS
The fan counter does not count the fan tach output pulses directly, because at low fan speeds it would take several seconds to accumulate a reasonably large and accurate count. Instead, the period of the fan revolution is measured by gating an onchip oscillator into the input of an 8-bit counter. The fan speed measuring circuit is initialized on the first rising edge of a fan tach pulse after monitoring is enabled by setting Bit 4 of the Configuration Register. It then starts counting on the rising edge of the second tach pulse and counts for four fan tach periods, until the rising edge of the sixth tach pulse, or until the counter overranges if the fan tach period is too long.
Fans generally do not overspeed if run from the correct voltage, so the failure condition of interest is under-speed due to electrical or mechanical failure. For this reason only low-speed limits are programmed into the Tach Limit Registers for the fans. These registers are at address 78h for Fan 1 and 79h for Fan 2. It should be noted that, since fan period rather than speed is being measured, the fan speed count will be larger the slower the fan speed. Therefore a fan failure fault will occur when the measurement exceeds the limit value.
Rev. 1 | Page 14 of 50 | www.onsemi.com
ADM1029
For the most accurate fan failure indication, the oscillator frequency should be chosen to give as large a limit value as possible without the counter overranging. A count close to 3/4 full-scale or 191 is the optimum value. For example, if a fan produces two tach pulses per revolution and the fan failure speed is to be 600 rpm, the oscillator frequency should be set to 940 Hz. This will give a count at the fail speed of: 940 4 60/600/2 = 188 If the oscillator frequency were only 470 Hz, the count would be 94, while an oscillator frequency of 1880 Hz cannot be used because the count would be 376 and the counter would overrange.
FAN MONITORING CYCLE TIME
12V VCC PULL-UP 4.7k TYP
TACH OUTPUT
TACH1 OR TACH2 ZD1* ZENER
FAN SPEED COUNTER
*CHOOSE ZD1 VOLTAGE APPROX. 0.8
VCC
Figure 9b. Fan with Tach. Pull-Up to Voltage >6.5 V (e.g., 12 V) Clamped with Zener Diode
If the fan has a strong pull-up (less than 1 k) to 12 V, or a totem-pole output, a series resistor can be added to limit the Zener current, as shown in Figure 9c. Alternatively, a resistive attenuator may be used, as shown in Figure 9d. R1 and R2 should be chosen such that: 2 V < VPULLUP x R2/(RPULLUP + R1 + R2) < 5 V The fan inputs have an input resistance of nominally 160 k to ground, so this should be taken into account when calculating resistor values. With a pull-up voltage of 12 V and pull-up resistor less than 1 k, suitable values for R1 and R2 would be 100 k and 47 k. This will give a high input voltage of 3.83 V.
12V VCC
Five complete tach periods are required to carry out a fan speed measurement Therefore, if the start of a fan measurement just misses a rising edge, the measurement can take almost six tach periods for each fan. The worst-case monitoring cycle time is when both fans are under speed and the fan speed counter counts up to its maximum value. The actual count takes 256 oscillator pulses over four tach periods, plus a further two tach periods or 128 oscillator pulses before the count starts. The total monitoring cycle time is therefore: tMEAS = 384/fOSC(FAN 1) + 384/fOSC(FAN 2) In order to read a valid result from the Fan Tach Value Registers, the total monitoring time allowed after starting the monitoring cycle should be greater than this.
TACH SIGNAL CONDITIONING
TACH O/P PULL-UP TYP <1k OR TOTEM-POLE R1 10k
TACH1 OR TACH2 ZD1 ZENER*
FAN SPEED COUNTER
Signal conditioning in the ADM1029 accommodates the slow rise and fall times typical of fan tachometer outputs. The maximum input signal range is 0 V to 5 V, even if VCC is less than 5 V. In the event that these inputs are supplied from fan outputs that exceed 0 V to 5 V, either resistive attenuation of the fan signal or diode clamping must be included to keep inputs within an acceptable range. Figures 9a to 9d show circuits for most common fan tach outputs. If the fan tach output has a resistive pull-up to VCC, it can be connected directly to the fan input, as shown in Figure 9a.
12V VCC
*CHOOSE ZD1 VOLTAGE APPROX. 0.8
VCC
Figure 9c. Fan with Strong Tach. Pull-Up to >VCC or Totem-Pole Output, Clamped with Zener and Resistor
12V VCC
<1k R1* TACH OUTPUT
TACH1 OR TACH2 R2*
FAN SPEED COUNTER
*SEE TEXT
PULL-UP 4.7k TYP TACH OUTPUT
TACH1 OR TACH2
Figure 9d. Fan with Strong Tach. Pull-Up to >VCC or Totem-Pole Output, Attenuated with R1/R2
FAN SPEED COUNTER
FAN SPEED CONTROL
Figure 9a. Fan with Tach Pull-Up to +VCC
If the fan output has a resistive pull-up to 12 V (or other voltage greater than 6.5 V), the fan output can be clamped with a Zener diode, as shown in Figure 9b. The Zener voltage should be chosen so that it is greater than VIH but less than 6.5 V, allowing for the voltage tolerance of the Zener. A value of between 3 V and 5 V is suitable.
Fan speed is controlled using pulsewidth modulation (PWM). The PWM outputs (Pins 1 and 24) give a pulse output with a programmable frequency (default 250 Hz) and a duty-cycle defined by the contents of the relevant fan speed register, or by the automatic fan speed control when this mode is enabled. The speed at which a fan runs is determined by fault conditions and the settings of various control and mask registers. A fan can only be driven if it is defined as being supported by the controller in register 02h. The ADM1029 supports up to two fans, so Bits 0 and 1 of this register are permanently set. This register is read-only.
Rev. 1 | Page 15 of 50 | www.onsemi.com
ADM1029
A fan will only be driven if it is defined as being supported by the system in register 03h. If Bit 0 of this register is set, it indicates that Fan 1 is installed. This is the power-on default. If Bit 1 is set, it indicates that Fan 2 is installed. This bit is set by the state of Pin 18 at power-up. This register is read/write and the default/power-on setting can be overwritten. If a fan is not supported in register 03h it will not be driven, even if it is physically installed. The PWM outputs are open-drain outputs. They require pull-up resistors and must be amplified and buffered to drive the fans.
Minimum Speed
* If Bit 1 of an AIN Behavior Register is set (50h--AIN0, 51h--AIN1), all fans controlled by the ADM1029 will go to alarm speed if the corresponding AIN high limit is exceeded. * If Bit 5 of an AIN Behavior Register is set, all fans controlled by the ADM1029 will go to alarm speed if an analog input crosses the corresponding AIN low limit, the direction depending on the setting of Bit 3 of the AIN control register. (0 = alarm when input goes below low limit, 1 = alarm when input goes above low limit). * If a thermal override occurs while the ADM1029 is in sleep mode, all fans controlled by the ADM1029 will run at alarm speed.
Hot-Plug Speed
The normal operating fan speed is set by the four LSBs of the Fan 1 and Fan 2 Minimum/Alarm Speed Registers (addresses 60h, 61h). These bits also set the minimum speed at which a fan will run in automatic control mode. These bits should be set to 05h. This corresponds to 33% PWM duty-cycle, which is the lowest speed at which most fans will run reliably. Fan(s) will run at minimum speed if there is no fault condition, automatic fan speed is disabled, and there are no other overriding conditions.
Alarm Speed
Hot-plug speed is set by the four LSBs of the Fan 1 and Fan 2 Configuration Registers (addresses 68h and 69h). The PWM frequency is set by Bits 4 and 5 of these registers, while Bits 6 and 7 set the number of pulses per revolution for fan speed measurement. Fan(s) will run at hot-plug speed if any of the following conditions occur, assuming the condition has not been masked using the Fan Event Mask Registers: * If a fan is unplugged, the other fan (if any) controlled by the ADM1029 will run at hot-plug speed. * Setting Bit 0 of register 08h forces Fan 1 to run at hot-plug speed (Set Fan x Hot-Plug Speed). * Setting Bit 1 of register 08h forces Fan 2 to run at hot-plug speed (Set Fan x Hot-Plug Speed). * When a GPIO pin is configured as an input by setting Bit 0 of the corresponding GPIO Behavior Register, and Bit 5 of the GPIO Behavior Register is also set, all fans controlled by the ADM1029 will go to hot-plug speed when the logic input is asserted (high or low, depending on the polarity bit, Bit 1 of the corresponding GPIO Behavior Register). * If Bit 6 of a Fan Fault Action Register is set (18h for Fan 1, 19h for Fan 2) the corresponding fan will go to hot-plug speed when CFAULT is pulled low by an external source. Note: If operating conditions and register settings are such that both alarm speed and hot-plug speed would be triggered, which one takes priority is determined by Bit 5 of the Fan 1 and Fan 2 Status Registers (addresses 10h and 11h). If this bit is set, hot-plug speed takes priority. If it is cleared, alarm speed takes priority.
Full Speed
Alarm speed is set by the four MSBs of the Fan 1 and Fan 2 Minimum/Alarm Speed Registers (addresses 60h, 61h). Fan(s) will run at alarm speed if any of the following conditions occurs, assuming the condition has not been masked out using the Fan Event Mask Registers: * Setting Bit 0 of register 07h forces Fan 1 to run at alarm speed (Set Fan x Alarm Speed Register). * Setting Bit 1 of register 07h forces Fan 2 to run at alarm speed (Set Fan x Alarm Speed Register). If monitoring is disabled by clearing Bit 4 of the Configuration Register, all fans controlled by the ADM1029 will run at alarm speed. * When a GPIO pin is configured as an input by setting Bit 0 of the corresponding GPIO Behavior Register, and Bit 4 of the GPIO Behavior Register is also set, all fans controlled by the ADM1029 will go to alarm speed when the logic input is asserted (high or low, depending on the polarity bit, Bit 1 of the corresponding GPIO Behavior Register). * If Bit 7 of a Fan Fault Action Register is set (18h--Fan 1, 19h --Fan 2) the corresponding fan will go to alarm speed when CFAULT is pulled low by an external source. * If a tach measurement exceeds the set limit, all fans controlled by the ADM1029 will run at alarm speed. * If a fan fault input pin is asserted (low), all fans controlled by the ADM1029 will run at alarm speed. * If Bit 1 of a Temp. Fault Action Register is set (40h--Local Sensor, 41h--Remote 1, 42h--Remote 2), all fans controlled by the ADM1029 will go to alarm speed if the corresponding temperature high limit is exceeded. * If Bit 5 of a Temp. Fault Action Register is set, all fans controlled by the ADM1029 will go to alarm speed if a temperature input crosses the corresponding temperature low limit, the direction depending on the setting of Bit 3 of the Temp. Control register. (0 = alarm when input goes below low limit, 1 = alarm when input goes above low limit).
Fans will run at full speed if the corresponding bits in the Set Fan x Full Speed Register (address 09h) are set: Bit 0 for Fan 1 and Bit 1 for Fan 2.
Fan Mask Registers
The effect of various conditions on fan speed can be enabled or disabled by mask registers. In all these registers, setting Bit 0 of the register enables Fan 1 to go to alarm speed or hot-plug speed if the corresponding event occurs, while setting Bit 1 enables Fan 2. Clearing these bits masks the effect of the corresponding event on fan speed. Registers 20h and 21h are Fan Event Mask Registers. Bits 0 and 1 of register 20h enable (bit set) or mask (bit clear) the effect of a Fan 1 fault (underspeed or fault input) on Fan 1 and Fan 2 speed. Similarly, Bits 0 and 1 of register 21h enable (bit set)
Rev. 1 | Page 16 of 50 | www.onsemi.com
ADM1029
or mask (bit clear) the effect of a Fan 2 Fault on Fan 1 and Fan 2 speed. Registers 38h to 3Eh are GPIO X Event Mask Registers. Bits 0 and 1 of these registers enable or mask the effect of a GPIO assertion on Fan 1 and Fan 2 speed. Note: Registers 48h to 4Ah are Temp. Cooling Action Registers. Bits 0 and 1 of these registers enable or mask the effect of Local, Remote 1, and Remote 2 temperature faults on Fan 1 and Fan 2 speed. These registers also determine which temperature channel controls each fan in automatic fan speed control mode, as described later. Registers 58h and 59h are AIN Event Mask Registers. Bits 0 and 1 of these registers enable or mask the effect of an AIN outof-limit event on Fan 1 and Fan 2 speed.
MODES OF OPERATION
duty cycle that most fans will run reliably at. Note that the PWM duty cycle values programmed in to these registers also define the PWM duty cycle that the fans will turn on at, in Automatic Fan Speed Control Mode. It is recommended that after powerup, the PWM duty cycle is set to 33% before enabling Automatic Fan Speed Control.
THERMAL TRIP MODE
The ADM1029 has three different modes of operation. These modes determine the behavior of the system. 1. PWM Duty Cycle Select Mode (directly sets fan speed under software control). 2. Thermal Trip Mode 3. Automatic Fan Speed Control Mode
PWM DUTY CYCLE SELECT MODE
The ADM1029 can thermally trip the fan(s) for simple on/off fan control, or 2-speed fan control. For example, a fan can be programmed to run at 33% duty cycle. If the temperature exceeds the high temperature limit set for that temperature channel, the fan can automatically trip and run at Alarm Speed. The fan will continue to run at Alarm Speed even if the temperature error condition subsides, until the Latch Temp Fault bit (Bit 7 of the Temp x Fault Action Reg) is cleared in software by writing a 0 to it. To configure Fan 1 normally, run at 33% but to thermally trip to Alarm Speed for a Remote 2 measured temperature of 70C, set up the following registers: 1. Configure the normal PWM duty cycle for Fan 1 to 33%. Fan 1 Minimum/Alarm Speed Reg (0x60) = 0xF5 2. Set the Remote 2 High Temperature Limit = 70C. Remote 2 Temp High Limit Reg (0x92) = 0x46 3. Configure Alarm Speed on Overtemperature function for Remote 2 Temperature channel. Set Bit 1 of Temp 2 Fault Action Reg (0x42) 4. Enable Fan 1 to be controlled by Remote 2 Temperature. Set Bit 0 of Temp 2 Cooling Action Reg (0x4A) Once the fan thermally trips to Alarm Speed, it will continue to run at Alarm Speed until the temperature drops below the High Temperature Limit and the Latch Temp Fault bit (Bit 7 of the Temp 2 Fault Action Reg) is cleared to 0.
EVENT LATCH BITS
The ADM1029 may be operated under software control by clearing bits <1:0> of the three Temp Cooling Action Registers (Reg 0x48, 0x49, 0x4A). Once under Software Control, each fan speed may be controlled by programming values of PWM Duty Cycle in to the device. Values of PWM Duty Cycle between 0% to 100% may be written to the four LSBs of the Fan 1 and Fan 2 Minimum/Alarm Speed Registers (addresses 60h, 61h). to control the speed of each fan. Table IV shows the relationship between hex values written to the Minimum/Alarm Speed Registers and PWM duty cycle obtained.
Table IV. PWM Duty Cycle Select Mode
Hex Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
PWM Duty Cycle 0% 7% 14% 20% 27% 33% Recommended 40% 47% 53% 60% 67% 73% 80% 87% 93% 100% (Default)
Certain events that occur will cause latch bits to be set in various registers on the ADM1029. Once a latch bit is set, it will need to be cleared by software for the system to return to normal operation. To detect if a latch bit has been set, the INT pin can be used to signal a latch event to the system supervisor. Alternatively, the Status Registers can be polled periodically, and any latch bits that are set can be cleared. The events that cause latch bits to be set are: 1. Thermal Events. If the fan is run at Alarm Speed on Overtemperature or Undertemperature, this will set the Latch Temp Fault bit (Bit 7 of the Temp x Fault Action Registers 0x40-0x42). 2. Missing Fan. If a fan is missing, i.e., has been unplugged, the Missing Latch bit (Bit 1 of Fan x Status Registers) is set. 3. Hotplugged Fan. If a new fan is inserted into the system, Bit 7 (Hotplug Latch bit) of the Fan x Status Register is set. 4. FAULT Asserted. If the fan becomes stuck and its FAULT output asserts low, Bit 2 (Fault Latch bit) of the Fan x Status register is set. 5. TACH Failure. If the fan runs underspeed or becomes stuck, then Bit 6 (Tach Fault Latch Bit) of the Fan x Status Register is set.
It is recommended that the minimum PWM duty cycle be set to 33% (0x05). This has been determined to be the lowest PWM
*Bits <3:0> set the Minimum PWM duty cycle, bits <7:4> set the Alarm Speed PWM duty cycle for each fan. Rev. 1 | Page 17 of 50 | www.onsemi.com
ADM1029
AUTOMATIC FAN SPEED CONTROL
PWM DUTY CYCLE - %
73 66 60 53 47 40 33 0
TR
The ADM1029 has a local temperature channel and two remote temperature channels, which may be connected to an on-chip diode-connected transistor on a CPU or a general-purpose discrete transistor. These three temperature channels may be used as the basis for an automatic fan speed control loop to drive fans using Pulsewidth Modulation (PWM).
HOW DOES THE CONTROL LOOP WORK?
TRANGE = 5 C
100
E = 10 C
GE = 20 C
93 87 80
=
40
C
ANG
NG
AN
TR
RA
= TR
A E NG
80
C
The Automatic Fan Speed Control Loop is shown in Figure 10.
SPIN UP FOR 2 SECONDS MAX
T
E
5 10
20
40 TEMPERATURE - C
60
80
FAN SPEED
TMIN
TMAX = TMIN + TRANGE
Figure 11. PWM Duty Cycle vs. Temperature Slopes (TRANGE)
MIN
TMIN TEMPERATURE
TMAX = TMIN + TRANGE
Figure 11 shows the different control slopes determined by the TRANGE value chosen, and programmed in to the ADM1029. TMIN was set to 0C to start all slopes from the same point. It can be seen how changing the TRANGE value affects the PWM Duty Cycle vs. Temperature Slope. Figure 12 shows how for a given TRANGE, changing the TMIN value affects the loop. Increasing the TMIN value will increase the TMAX (temperature at which the fan runs full speed) value, since TMAX = TMIN + TRANGE. Note, however, that the PWM Duty Cycle versus Temperature slope remains exactly the same. Changing the TMIN value merely shifts the control slope.
100 93 PWM DUTY CYCLE - %
C
Figure 10. Automatic Fan Speed Control
In order for the fan speed control loop to work, certain loop parameters need to be programmed in to the device: 1. T MIN. This is the temperature at which a fan should switch on and run at minimum speed. The fan will only turn on once the temperature being measured rises above the TMIN value programmed. The fan will spin up for a predetermined time (default = 2 secs). See Fan Spin-Up section for more details. 2. TRANGE. This will be the temperature range over which the ADM1029 will automatically adjust fan speed. As the temperature increases beyond TMIN, the PWM duty cycle will be increased accordingly. The TRANGE parameter actually defines the fan speed versus temperature slope of the control loop. 3. TMAX. This is defined as the temperature at which a fan will be at its maximum speed. At this temperature, the PWM duty cycle driving the fan will be 100%. TMAX is given by TMIN + TRANGE. Since this parameter is the sum of the TMIN and TRANGE parameters, it does not need to be programmed into a register on-chip. 4. Programmable hysteresis is included in the control loop to prevent the fans continuously switching on and off if the temperature is close to TMIN. The fans will continue to run until such time as the temperature drops below TMIN-THYST. The four MSBs of the TRANGE/T HYST registers (Registers 0x88, 0x89, 0x8A) contain a temperature hysteresis value that can be programmed from 0001 to 1111. This allows a temperature hysteresis range from 1C to 15C for each temperature measurement channel.
C
87 80
RA
40
0
=4
=
NG
NG
RA
73 66 60 53 47 40 33 0 TMIN
T
T
RA
T
NG
E=
E
E
40
C
20
40 TEMPERATURE - C
60
80
TMAX = TMIN + TRANGE
Figure 12. Effect of Increasing TMIN Value on Control Loop
FAN SPIN-UP
As previously mentioned, once the temperature being measured exceeds the TMIN value programmed, the fan will turn on at minimum speed (default = 33% duty cycle). However, the problem with fans being driven by PWM is that 33% duty cycle is not enough to reliably start the fan spinning. The solution is to
Rev. 1 | Page 18 of 50 | www.onsemi.com
ADM1029
spin the fan up for a predetermined time, and once the fan has spun up, its running speed may be reduced in line with the temperature being measured.
PWM DUTY CYCLE - %
100 93 87 80
66 60 53 47 40
Bits 2:0 000 001 010 011 100 101 110 111
Spin-Up Times (Fan Spin-Up Register) 16 Seconds 8 Seconds 4 Seconds 2 Seconds (Default) 1 Second 1/4 Second 1/16 Second 1/64 Second
33 0 TMIN 20 40 60 TMAX = TMIN + TRANGE
LOCAL TEMPERATURE - C
100 93
Once the Automatic Fan Speed Control Loop parameters have been chosen, the ADM1029 device may be programmed. The ADM1029 is placed into Automatic Fan Speed Control Mode by writing to the three Temperature Cooling Action Registers (Registers 0x48, 0x49, 0x4A). The device powers up in Automatic Fan Speed Control Mode by default, as long as the TMIN/ Install pin (Pin 18) does not have the disable option selected (TMIN/Install pin tied low or high). The default setting is that both fans will run at the fastest speed calculated by all three temperature channels. The control mode offers flexibility in that the user can decide which temperature channel/channels control each fan (five options).
Table VI. Automatic Mode Fan Behavior
PWM DUTY CYCLE - %
87 80 73 66 60 53 47 40 33 0 TMIN 20 40 REMOTE TEMPERATURE - C 70 80 TMAX = TMIN + TRANGE
T
Table V. Fan Spin-Up Times
a.
RA NG E
=4
= TR
GE AN
The ADM1029 allows fan spin-up times between 1/64 second and 16 seconds. The Fan Spin-Up Register (Register 0x0C) allows the spin-up time for the fans to be programmed. Bit 3 of this register, when set, disables fan spin-up for both fans.
0C
80 C
73
Option 1
Temperature Cooling Action Bit 0 Register 0x49 and/or Bit 1 Reg 0x4A = Remote Temp 1 Controls Fan 1, Remote Temp 2 Controls Fan 2 Bit 0 Register 0x48 and Bit 1 Register 0x48 = 1 Local Temp Controls Fan 1 and/or Fan 2 Bit 0 Register 0x49 and Bit 1 Register 0x49 = Remote Temp 1 Controls Fan 1 and/or Fan 2 Bit 0 Register 0x4A and Bit 1 Register 0x4A = Remote Temp 2 Controls Fan 1 and/or Fan 2 Bits 0, 1 Reg 0x48, 0x49, 0x4A = 1 Max Speed Calculated by Local and Remote Temperature Channels Controls Fans 1 and/or 2
b. Figure 13. Max Speed Calculated by Local and Remote Temperature Control Loops Drives Fans
2 3 4 5
The local temperature's TMAX will thus be 60C. Figure 13b shows the control loop for the Remote 1 Temperature channel. Its TMIN value has been set to 0C, while its TRANGE = 80C. Therefore, the Remote 1 Temperature's TMAX value will be 80C. If both temperature channels measure 40C, both control loops will calculate a PWM duty cycle of 66%. Therefore, the fans will be driven at 66% duty cycle. If both temperature channels measure 20C, the local channel will calculate 33% PWM duty cycle, while the Remote 1 channel will calculate 50% PWM duty cycle. Thus, the fans will be driven at 50% PWM duty cycle. Consider the local temperature measuring 60C, while the Remote 1 temperature is measuring 70C. The PWM duty cycle calculated by the local temperature control loop will be 100% (since the temperature = TMAX). The PWM duty cycle calculated by the Remote 1 temperature control loop at 70C will be approximately 90%. So the fans will run full speed (100% duty cycle). Remember that the fan speed will be based on the fastest speed calculated, and is not necessarily based on the highest temperature measured. Depending on the control loop parameters programmed, a lower temperature on one channel may actually calculate a faster speed than a higher temperature on another channel.
When Option 5 is chosen, this offers increased flexibility. The Local and Remote temperature channels can have independently programmed control loops with different control parameters. Whichever control loop calculates the fastest fan speed based on the temperature being measured, drives both fans. Figure 13 shows how the fan's PWM duty cycle is determined by two independent control loops. This is the type of Automode Fan Behavior seen when Bits 0 and 1 of all three Temperature Cooling Action Registers = 11. Figure 13a shows the control loop for the Local Temperature channel. Its TMIN value has been programmed to 20C, and its TRANGE value is 40C.
Rev. 1 | Page 19 of 50 | www.onsemi.com
ADM1029
PROGRAMMING THE AUTOMATIC FAN SPEED CONTROL LOOP Table VII. Programming PWM Duty Cycle
1. Program a value for TMIN. 2. Program a value for the slope TRANGE. 3. TMAX = TMIN + TRANGE. 4. Program a value for Fan Spin-up Time. 5. Program the desired Automatic Fan Speed Control Mode Behavior, i.e., which temperature channel controls each fan.
OTHER CONTROL LOOP PARAMETERS?
Decimal Value 00 01 02 03 04 05 06 07 08 09 10 (0x0A) 11 (0x0B) 12 (0x0C) 13 (0x0D) 14 (0x0E) 15 (0x0F)
PWM Duty Cycle 0% 7% 14% 20% 27% 33% Recommended 40% 47% 53% 60% 67% 73% 80% 87% 93% 100% (Default)
Having programmed all the above loop parameters, are there any other parameters to worry about? TMIN was defined as being the temperature at which a fan switched on and ran at minimum speed. This minimum speed should be set to 33%. If the minimum PWM duty cycle is programmed to 33%, the fan control loops will operate as previously described. It should be noted, however, that changing the minimum PWM duty cycle affects the control loop behavior.
100 93
*Bits <3:0> set the Minimum PWM duty cycle for Automatic Mode. Bits <7:4> set the Alarm Speed PWM duty cycle.
The temperature at which each fan will run full speed (100% duty cycle) is given by: TMAX = TMIN + (( Max DC-Min DC) x TRANGE/10) where,
40
PWM DUTY CYCLE - %
87 80 73 66 60
3
NG
C
2
TMAX TMIN Max DC Min DC TRANGE
Example 1
= = = =
1
53 47 40 33
Temperature at which fan runs full speed Temperature at which fan will turn on Maximum Duty Cycle (100%) = 15 decimal Duty Cycle at TMIN, programmed into Fan Speed Config Register (default = 33% = 5 decimal) = PWM Duty Cycle versus Temperature Slope = 0C, TRANGE = 40C = 53% = 8 decimal (Table VII)
T
RA
E=
TMIN Min DC
16 28 40 60 TEMPERATURE - C
0 TMIN
Calculate TMAX
Figure 14. Effect of Changing Minimum Duty Cycle on Control Loop with Fixed TMIN and TRANGE Values
TMAX = TMIN + (( Max DC-Min DC) x TRANGE/10) TMAX = 0 + ((100% DC - 53% DC) x 40/10) TMAX = 0 + ((15 - 8)x 4) = 28
Slope 1 of Figure 14 shows TMIN set to 0C and the TRANGE chosen is 40C. In this case, the fan's PWM duty cycle will vary over the range 33% to 100%. The fan will run full speed at 40C. If the minimum PWM duty cycle at which the fan runs at TMIN is changed, its effect can be seen on Slopes 2 and 3. Take Case 2, where the minimum PWM duty cycle is reprogrammed from 33% (default) to 53%. The fan will actually reach full speed at a much lower temperature, 28C. Case 3 shows that when the minimum PWM duty cycle was increased to 73%, the temperature at which the fan ran full speed was 16C. So the effect of increasing the minimum PWM duty cycle, with a fixed TMIN and fixed TRANGE, is that the fan will actually reach full speed (TMAX) at a lower temperature than TMIN + TRANGE. How can TMAX be calculated? In Automatic Fan Speed Control Mode, the registers holding the minimum PWM duty cycle at TMIN, are the Minimum/ Alarm Speed Registers (addresses 60h, 61h). Table VII shows the relationship between the decimal values written to the Minimum/Alarm Speed Registers and PWM duty cycle obtained.
TMAX = 28 C. (As seen on Slope 2 of Figure 14)
Example 2
TMIN Min DC
= 0C, TRANGE = 40C = 73% = 11 decimal (Table VII)
Calculate TMAX
TMAX = TMIN + ((Max DC-Min DC) x TRANGE/10) TMAX = 0 + ((100% DC - 73% DC) x 40/10) TMAX = 0 + ((15 - 11) x 4) = 16
TMAX = 16 C. (As seen on Slope 3 of Figure 14)
Example 3
TMIN Min DC
= 0C, TRANGE = 40C = 33% = 5 decimal from Table IV
Calculate TMAX
TMAX = TMIN + ((Max DC-Min DC) x TRANGE/10) TMAX = 0 + ((100% DC - 33% DC) x 40/10) TMAX = 0 + ((15 - 5) x 4) = 40
TMAX = 40 C. (As seen on Slope 1 of Figure 14)
Rev. 1 | Page 20 of 50 | www.onsemi.com
ADM1029
PROGRAM FAN MINIMUM DUTY CYCLE FAN 1 (REG 0x60) FAN 2 (REG 0x61) TEMP COOLING ACTION (CONFIGURE REG 0x48 FOR LOCAL TEMP, REG 0x49 FOR REMOTE 1 TEMP AND REG 0x4A FOR REMOTE 2 TEMP) BIT 0 (REG 0x49) AND/OR BIT 1 (REG 0x4A) = 1 REMOTE 1 TEMP CONTROLS FAN 1 REMOTE 2 TEMP CONTROLS FAN 2 BIT 0 (REG 0x48) AND BIT 1 (REG 0x48) = 1 LOCAL TEMP CONTROLS FAN 1 AND/OR FAN 2 BIT 0 (REG 0x49) AND BIT 1 (REG 0x49) = 1 REMOTE 1 TEMP CONTROLS FAN 1 AND/OR FAN 2 BIT 0 (REG 0x4A) AND BIT 1 (REG 0x4A) = 1 REMOTE 2 TEMP CONTROLS FAN 1 AND/OR FAN 2 BIT 0, 1 (REG 0x48, 0x49, 0x4A) = 1 FAN 1 AND/OR FAN 2 RUNS AT FASTEST SPEED CALCULATED BY ALL TEMPERATURE CHANNELS
OPTION 1
OPTION 2 CONFIGURE TEMP COOLING ACTION LOCAL TEMP (REG 0x48) REMOTE 1 TEMP (REG 0x49) REMOTE 2 TEMP (REG 0x4A)
OPTION 3
OPTION 4
OPTION 5 PROGRAM FAN START TEMPERATURE, TMIN LOCAL TEMP (REG 0x80) REMOTE 1 TEMP (REG 0x81) REMOTE 2 TEMP (REG 0x82) REMOTE 1 TEMPERATURE
FAN 1
FAN 1
PROGRAM TEMP-TO-FAN SPEED CONTROL SLOPE, TRANGE LOCAL TEMP (REG 0x88) REMOTE 1 TEMP (REG 0x89) REMOTE 2 TEMP (REG 0x8A) REMOTE 2 TEMPERATURE CONFIGURE CONTROL LOOP HYSTERESIS LOCAL TEMP (REG 0x88) REMOTE 1 TEMP (REG 0x89) REMOTE 2 TEMP (REG 0x8A) REMOTE 1 TEMPERATURE
ADM1029
ADM1029
LOCAL TEMP
OPTION 1 FAN 2
OPTION 2
FAN 2
FAN 1
REMOTE 1 TEMPERATURE
FAN 1
CONFIGURE FAN SPIN-UP TIME (REGISTER 0x0C)
ADM1029
CONFIGURE PWM DRIVE FREQUENCY FAN 1 (REG 0x68) FAN 2 (REG 0x69) REMOTE 2 TEMPERATURE REMOTE 2 TEMPERATURE FAN 2
ADM1029
OPTION 3
OPTION 4
FAN 2
CONFIGURE TACH OSCILLATOR FREQUENCY FAN 1 (REG 0x68) FAN 2 (REG 0x69)
REMOTE 1 TEMPERATURE
FAN 1
MEASURE FAN SPEED FAN 1 (REG 0x70) FAN 2 (REG 0x71)
ADM1029
LOCAL TEMP
REMOTE 2 TEMPERATURE
OPTION 5
FAN 2
Figure 15. Configuring Automatic Fan Speed Control
Rev. 1 | Page 21 of 50 | www.onsemi.com
ADM1029
Table VIII. Resistor Ratios for Setting T MIN and Number of Fans Installed Using TMIN/INSTALL Pin (Pin 18)
3 MSBs of ADC 111 110 101 100 011 010 001 000
Ideal Ratio R2/(R1 + R2) N/A 0.8125 0.6875 0.5625 0.4375 0.3125 0.1875 N/A
R1 (k ) 0 18 22 12 15 47 82
R2 (k ) 82 47 15 12 22 18 0
Actual R2/(R1 + R2) 1 0.82 0.6812 0.5556 0.4444 0.3188 0.18 0
Error (%) 0 0.75 -0.63 -0.69 0.69 0.63 -0.75 0
TMIN Disabled 48C 40C 32C 32C 40C 48C Disabled
Fans Installed 2 2 2 2 1 1 1 1
In this case, since the Minimum Duty Cycle is the default 33%, the equation for TMAX reduces to: TMAX = TMIN + ((Max DC - Min DC) x TRANGE/10) TMAX = TMIN + ((15 - 5) x TRANGE/10) TMAX = TMIN + (10 x TRANGE/10) TMAX = TMIN + TRANGE
ENABLING AUTOMATIC FAN SPEED CONTROL USING TMIN/INSTALL PIN (PIN 18)
FAN-RELATED REGISTERS
Table IX is a list of registers on the ADM1029 that are specific to fan speed measurement and control:
Table IX. Fan-Specific Registers
Address 0x02 0x03 0x07 0x08 0x09 0x10 0x11 0x18 0x19 0x20 0x21 0x48 0x49 0x4A 0x60 0x61 0x68 0x69 0x70 0x71 0x78 0x79
Description Fans Supported By Controller Fans Supported In System Set Fan x Alarm Speed Set Fan x Hot-Plug Speed Set Fan x Full Speed Fan 1 Status Fan 2 Status Fan 1 Fault Action Fan 2 Fault Action Fan 1 Event Mask Fan 2 Event Mask Local Temp Cooling Action Remote 1 Cooling Action Remote 2 Cooling Action Fan 1 Minimum/Alarm Speed Fan 2 Minimum/Alarm Speed Fan 1 Configuration Fan 2 Configuration Fan 1 Tach Value Fan 2 Tach Value Fan 1 Tach High Limit Fan 2 Tach High Limit
Automatic fan control can also be enabled in hardware by Pin 18 (TMIN/INSTALL). This is an 8-level input with multiple functions, which is sampled only at power-up. If only one fan is installed, the voltage on Pin 18 should be kept at less than VCC/2, which clears Bit 1 of register 03h. Within this voltage range, four voltage levels define the minimum temperature at which the fan will operate in automatic speed control mode. If two fans are installed, the voltage on Pin 18 should be between VCC/2 and VCC, which sets Bit 1 of register 03h. Within this voltage range, four voltage levels define the minimum temperature at which the fans will operate in automatic speed control mode. Resistor values for setting the voltage on Pin 18 are given in Table VIII. If automatic fan speed control is not used, Pin 18 can simply be strapped to ground (one fan) or VCC (two fans), depending on how many fans are installed. Under this condition, the fans will run full speed until the device is written to by software to change fan speed. When automatic fan speed control is enabled at power-up by the TMIN/INSTALL pin, Bit 4 of the Configuration register is set to enable monitoring, and Bits 0 and 1 of all Temp. Cooling Action Registers are set, so any temperature channel will automatically control all fans that are installed. Note: if automatic fan speed control is enabled and an event occurs that would cause a fan to go to alarm or hot-plug speed (e.g., temperature fault), that event will override the automatic fan speed control. If the event affects only one fan, the other fan will remain under automatic control.
FAN CONFIGURATION REGISTERS
Registers 0x68 and 0x69 are the Fan 1 and Fan 2 Configuration Registers. These allow the PWM output frequencies to be selected for each fan. The default PWM drive frequency is 250 Hz. Bits <7:6> adjust the fan tach oscillator frequency for fan tach measurements. Bits <3:0> allow the Hot Plug PWM duty cycle value for each fan to be programmed. Figures 16 and 17 show how to configure the fans to handle thermal or fault events.
Rev. 1 | Page 22 of 50 | www.onsemi.com
ADM1029
FAN FAULT ACTION (CONFIGURE REG 0x18 FOR FAN 1, REG 0x19 FOR FAN 2) CONFIGURE FAN NORMAL SPEED FAN 1 (REG 0x60) FAN 2 (REG 0x61) BIT 0 = 1 BIT 1 = 1 BIT 2 = 1 BIT 3 = 1 BIT 4 = 1 BIT 5 = 1 BIT 6 = 1 BIT 7 = 1 7 ASSERT CFAULT ON FAN FAULT (TACH FAILURE OR FAULT ASSERTION) ASSERT INT ON FAN FAULT (TACH FAILURE OR FAULT ASSERTION) ASSERT CFAULT IF FAN HOT UNPLUGGED ASSERT INT IF FAN HOT UNPLUGGED THERMAL OVERRIDE IF IN SLEEP MODE (FAN RUNS AT ALARM SPEED) DRIVE FAULT LOW IF A FAN FAULT IS DETECTED IF CFAULT PULLED LOW EXTERNALLY, RUN FAN AT HOT-PLUG SPEED IF CFAULT PULLED LOW EXTERNALLY, RUN FAN AT ALARM SPEED 6 5 4 3 2 1 0
SET FAN 1 = 33% SET FAN 2 = 33%
DEFAULTS FAN 1 = 100% FAN 2 = 100%
CONFIGURE FAN ALARM SPEED FAN 1 (REG 0x60) FAN 2 (REG 0x61)
FAN TACH FAILURE OR FAULT PIN LOW? DEFAULTS FAN 1 = 100% FAN 2 = 100% CONFIGURE FAN HOT-PLUG SPEED FAN 1 (REG 0x68) FAN 2 (REG 0x69) FAN TACH FAILURE OR FAULT PIN LOW?
CFAULT YES
INT YES
CONFIGURE FAN FAULT ACTION FAN 1 (REG 0x18) FAN 2 (REG 0x19)
HAS A FAN BEEN HOT UNPLUGGED?
CFAULT YES
HAS A FAN BEEN HOT UNPLUGGED? OVERTEMPERATURE DETECTED IN SLEEP MODE? FAN TACH FAILURE OR FAULT PIN LOW?
INT YES
FAN RUNS AT ALARM SPEED YES
CONFIGURE FAN FAULT MASK REGISTERS FAN 1 (REG 0x20) FAN 2 (REG 0x21)
YES
HAS CFAULT BEEN PULLED LOW?
FAN RUNS AT HOT-PLUG SPEED YES
HAS CFAULT BEEN PULLED LOW?
FAN RUNS AT ALARM SPEED YES
FAN TACH FAILURE OR FAULT PIN LOW? BIT 0 = 1 RUN FAN 1 AT ALARM SPEED IF FAN FAULT IS DETECTED RUN FAN 2 AT ALARM SPEED IF FAN FAULT IS DETECTED DON'T CARE
FAN 1 RUNS ALARM SPEED YES
BIT 1 = 1
BITS 2 - 7
FAN FAULT MASK (CONFIGURE REG 0x20 FOR FAN 1, REG 0x21 FOR FAN 2)
FAN TACH FAILURE OR FAULT PIN LOW?
FAN 2 RUNS ALARM SPEED YES
Figure 16. Fan Configuration Flowchart
Rev. 1 | Page 23 of 50 | www.onsemi.com
ADM1029
GPIO EVENT MASK (CONFIGURE REG 0x38 FOR GPIO0, REG 0x39 FOR GPIO1.....REG 0x3E FOR GPIO6) BIT 0 = 1 FAN 1 RUNS AT ALARM OR HOT-PLUG SPEED IF GPIO PIN IS ASSERTED FAN 2 RUNS AT ALARM OR HOT-PLUG SPEED IF GPIO PIN IS ASSERTED DON'T CARE IS GPIO PIN ASSERTED? YES FAN RUNS AT ALARM OR HOT-PLUG SPEED
BIT 1 = 1
BITS 2 - 7 CONFIGURE GPIO EVENT MASK REGISTERS (REG 0x38 - 0x3E)
PROGRAM FAN START TEMPERATURE, TMIN LOCAL TEMP (REG 0x80) REMOTE 1 TEMP (REG 0x81) REMOTE 2 TEMP (REG 0x82)
CONFIGURE TEMP COOLING ACTION LOCAL TEMP (REG 0x48) REMOTE 1 TEMP (REG 0x49) REMOTE 2 TEMP (REG 0x4A)
PROGRAM TEMP-TO-FAN SPEED CONTROL SLOPE, TRANGE LOCAL TEMP (REG 0x88) REMOTE 1 TEMP (REG 0x89) REMOTE 2 TEMP (REG 0x8A)
AUTOMATIC FAN SPEED CONTROL CONFIGURATION (REFER TO AUTOMATIC FAN SPEED CONTROL FLOWCHART)
CONFIGURE AIN EVENT MASK REGISTERS AIN1 (REG 0x58) AIN2 (REG 0x59)
CONFIGURE CONTROL LOOP HYSTERESIS CONFIGURE FAN SPIN-UP TIME REGISTER 0x0C LOCAL TEMP (REG 0x88) REMOTE 1 TEMP (REG 0x89) REMOTE 2 TEMP (REG 0x8A)
CONFIGURE PWM DRIVE FREQUENCY FAN1 (REG 0x68) FAN2 (REG 0x69)
AIN EVENT MASK (CONFIGURE REG 0x58 FOR AIN 0, REG 0x59 FOR AIN 1) BIT 0 = 1 FAN 1 RUNS AT ALARM SPEED IF AIN OUT-OF-LIMIT EVENT OCCURS FAN 2 RUNS AT ALARM SPEED IF AIN OUT-OF-LIMIT EVENT OCCURS DON'T CARE IS AIN PIN ASSERTED? YES FAN RUNS AT ALARM SPEED
BIT 1 = 1
CONFIGURE TACH OSCILLATOR FREQUENCY FAN1 (REG 0x68) FAN2 (REG 0x69)
BITS 2 - 7
MEASURE FAN SPEED FAN1 (REG 0x70) FAN2 (REG 0x71)
Figure 17. Fan Configuration Flowchart (Continued)
Rev. 1 | Page 24 of 50 | www.onsemi.com
ADM1029
RESET INPUT
Pin 12 is an active-low system RESET input. Taking this pin low will generate a system reset, which will reset all registers to their default values.
ANALOG INPUTS
Pins 19 and 20 of the ADM1029 are dual-function pins. They may be configured as general-purpose logic I/O pins by setting Bits 0, 1 of the GPIO Present/AIN Register (address 05h) or as 0 V to 2.5 V analog inputs by clearing these bits. In the analog input mode, Pins 19 and 20 have an input range of 0 V to 2.5 V. By suitable input scaling, the analog input may be configured to measure other voltage ranges such as system power supply voltages. If more than one ADM1029 is used in a system, several such voltages may be monitored. The measured values of AIN0 and AIN 1 are stored in the AIN0 and AIN1 Value Registers (addresses B8h and B9h) and are compared to high and low limits stored in the AIN0 and AIN1 High and Low Limit Registers (addresses A8h, A9h and B0h, B1h). The response of the ADM1029 to an out-of-limit measurement on AIN0 or AIN1 depends on the status of the AIN0 and AIN1 Behavior Registers (Registers 50h, 51h). The response of CFAULT, INT, and fan speed to temperature events depends on the setting of these registers, as detailed in the register tables later in this data sheet. Figure 18 shows how the AIN pins can be configured to respond to different events.
ANALOG MONITORING CYCLE
* If Bit 6 of a Temp. Fault Action Register is set, INT will be asserted if a temperature input crosses the corresponding temperature low limit, the direction depending on the setting of Bit 3 of the Temp. Fault Action register. (0 = INT when temperature goes below low limit, 1 = INT when temperature goes above low limit). * If Bit 1 of a Fan Fault Action Register (18h or 19h) is set, INT will be asserted when a tach measurement for the corresponding fan exceeds the set limit . * If Bit 1 of a Fan Fault Action Register (18h or 19h) is set, INT will be asserted when the fan fault input pin for the corresponding fan is asserted (low). * If Bit 2 of an AIN Behavior Register is set (50h--AIN0, 51h-- AIN1), INT will be asserted if the corresponding AIN high limit is exceeded. * If Bit 6 of an AIN Behavior Register is set, INT will be asserted if the corresponding analog input crosses its AIN low limit, the direction depending on the setting of Bit 3 of the AIN Behavior register. (0 = INT when input goes below low limit, 1 = INT when input goes above low limit).
FAN FREE-WHEELING TEST
The ADM1029 performs a sequential "round-robin," monitoring cycle on all analog inputs and temperature inputs that are enabled. A conversion on AIN0 or AIN1 typically takes 11.6 ms, while an external temperature conversion takes 185.6 ms.
INTERRUPT (INT) OUTPUT
The INT output is an open-drain output with selectable polarity, intended to communicate fault conditions to the host processor. The polarity is set to active low by clearing Bit 7 of the Configuration Register (address 01h) or to active high by setting this bit. INT can be asserted if any of the following conditions occur: * A hot-plug event. * Setting Bit 6 of the Configuration Register (address 01h) forces INT to be asserted. * When a GPIO pin is configured as an input by setting Bit 0 of the corresponding GPIO Behavior Register and Bit 3 of the GPIO Behavior Register is also set, INT will be asserted when the logic input is asserted (high or low, depending on the polarity bit, Bit 1 of the corresponding GPIO Behavior Register). * If Bit 2 of a Temp. Fault Action Register is set (40h--Local Sensor, 41h--Remote 1, 42h--Remote 2), INT will be asserted if the corresponding temperature high limit is exceeded.
The Fan Free Wheeling Test is used to diagnose fans connected to the ADM1029 to ensure that they are operating correctly. Large fans tightly coupled in a duct can affect each other's airflow. If one fan has failed it may not be apparent, as the other fan moving can suck air through the faulty fan causing it to spin. The ADM1029 will spin each fan up separately with the other powered down and measure the fan speed of both. When it tries to spin the failed fan with the working fan off, the fan speed measurement will fail, and the faulty fan will be detected. The Fan Free-Wheel Test can be invoked at any time in software by setting Bit 3 of the Configuration Register (Reg. 0x01). The Fan Free-Wheel Test normally takes about 10 seconds. Once the Fan Free-Wheel test has completed, Bit 3 will automatically clear to 0.
Automatic Fan Free-Wheel Test
Whenever a fan is hot-plugged, the Fan Free-Wheel Test is automatically invoked. Bit 3 gets set high automatically and once the test has completed, self-clears to 0. If 2 fans are installed in the system, the Fan Free-Wheel Test is invoked by removing the suspect fan and hotplugging a new one. When the suspect fan (e.g., Fan 1) is removed, the Missing bit (Bit 0) and Missing Latch bit (Bit 1) of the Fan 1 Status Register are set. Fan 2 will then automatically run at HotPlug Speed. If the faulty fan is replaced, the HotPlug Latch bit (Bit 7) is set and the Missing bit (Bit 0) self-clears. (However, the Missing Latch bit remains set.) Fan 2 will return to its previous value automatically and the Fan Free-Wheel Test is invoked. Fan 1 is run at 100% while Fan 2 is turned off. Fan 2 is then run at 100% with Fan 1 turned off. Both fans are then spun-up for the Fan Spin-up time. Note that the Hotplug Latch bit and Missing Latch bit remains set (Bits 7 and 1). These need to be cleared to 0 before a subsequent Fan Free-Wheel Test can occur. Otherwise, subsequent fan removals and insertions are ignored.
Rev. 1 | Page 25 of 50 | www.onsemi.com
ADM1029
AIN PINS ENABLE (REG 0x05) ENABLE PINS FOR AIN FUNCTION (REGISTER 0x05) BIT 0 = 0 BIT 1 = 0 BIT 2 - 7 PIN 19 CONFIGURED AS AIN0 PIN 20 CONFIGURED AS AIN1 RESERVED FOR OTHER FUNCTIONS
AIN PINS BEHAVIOR (REG 0x50 CONFIGURES AIN0, REG 0x51 CONFIGURES AIN1) CONFIGURE AIN PINS BEHAVIOR AIN0 (REG 0x50) AIN1 (REG 0x51) BIT 0 = 1 BIT 1 = 1 BIT 2 = 1 BIT 3 = 0 BIT 3 = 1 BIT 4 = 1 BIT 5 = 1 BIT 6 = 1 CONFIGURE AIN EVENT MASK AIN0 (REG 0x58) AIN1 (REG 0x59) BIT 7 = 1 CFAULT ASSERTED IF AIN VALUE EXCEEDS AIN HIGH LIMIT FANS RUN ALARM SPEED IF AIN VALUE EXCEEDS AIN HIGH LIMIT INT ASSERTED IF AIN VALUE EXCEEDS AIN HIGH LIMIT ALARM GENERATED (INT, CFAULT, OR ALARM SPEED) WHEN AIN GOES BELOW AIN LOW LIMIT ALARM GENERATED (INT, CFAULT, OR ALARM SPEED) WHEN AIN GOES ABOVE AIN LOW LIMIT CFAULT ASSERTED IF AIN VALUE EXCEEDS AIN LOW LIMIT. BIT 3 DECIDES WHETHER CFAULT IS ASSERTED GOING ABOVE OR BELOW THE LOW LIMIT FANS RUN ALARM SPEED IF AIN VALUE CROSSES THE AIN LOW LIMIT. BIT 3 DECIDE WHETHER ALARM SPEED IS TRIGGERED GOING ABOVE OR BELOW THE LOW LIMIT INT ASSERTED IF AIN VALUE CROSSES THE AIN LOW LIMIT. BIT 3 DECIDES WHETHER INT IS ASSERTED GOING ABOVE OR BELOW THE LOW LIMIT THIS BIT LATCHES AN OUT-OF-LIMIT AIN EVENT. CLEARED BY WRITING A '0'
7
6
5
4
3
2
1
0
AIN EVENT MASK (CONFIGURE REG 0x58 FOR AIN0, REG 0x59 FOR AIN1) BIT 0 = 1 RUN FAN 1 AT ALARM SPEED IF AIN OUT-OFLIMIT EVENT IS DETECTED RUN FAN 2 AT ALARM SPEED IF AIN OUT-OFLIMIT EVENT IS DETECTED RESERVED - READ BACK ZERO
IS AIN VALUE > AIN HIGH LIMIT?
BIT 1 = 1
CFAULT IS AIN VALUE > AIN HIGH LIMIT? YES
BITS 2 - 7
FANS RUN ALARM SPEED IS AIN VALUE > AIN HIGH LIMIT? YES
CONFIGURE AIN HIGH LIMITS AIN0 (REG 0xA8) AIN1 (REG 0xA9) AIN ABOVE OR BELOW LOW AIN LIMIT?
INT YES 0 = ALARM BELOW AIN LOW LIMIT
CONFIGURE AIN LOW LIMITS AIN0 (REG 0xB0) AIN1 (REG 0xB1)
1 = ALARM ABOVE AIN LOW LIMIT HAS AIN VALUE EXCEEDED AIN LOW LIMIT?
CFAULT HAS AIN VALUE EXCEEDED AIN LOW LIMIT? YES
MEASURE AIN VOLTAGES AIN0 (REG 0xB8) AIN1 (REG 0xB9)
FANS RUN ALARM SPEED HAS AIN VALUE EXCEEDED AIN LOW LIMIT? YES
INT YES
Figure 18. Configuring AIN0 and AIN1 Pins
Rev. 1 | Page 26 of 50 | www.onsemi.com
ADM1029
GENERAL PURPOSE LOGIC INPUT/OUTPUTS CFAULT OUTPUT
The ADM1029 has six dual-function pins (see Pin Function Descriptions section) that may be configured as general-purpose Logic I/O pins by setting the appropriate bit(s) of the GPIO Present/AIN Register (address 05h) or as their alternate functions by clearing these bits. When configured as GPIO pins, each GPIO pin has a Behavior Register associated with it (Registers 28h to 2Eh) that may be used to configure the operation of the pin. The GPIO pins may be configured as inputs or outputs. When used as inputs, they may be configured to: * Be active high or active low. * Set/clear a bit in the Behavior Register when GP input is asserted/deasserted. * Latch a bit in the Behavior Register when GP input is asserted (must be cleared by software). * Assert CFAULT when GP input asserted. * Assert INT when GP input asserted. * Set fan(s) to alarm speed when GP input asserted. * Set fan(s) to hot-plug speed when GP input asserted. When used as outputs, they may be configured to: * Be active high or low * Be asserted if a High Temperature Limit is exceeded. * Be asserted if a temperature measurement falls below a low limit. * Be asserted if a fan fault is detected. * Be asserted if a fan tach limit is exceeded. * Be asserted if an AIN high limit is exceeded. * Be asserted if an analog input falls below a low limit. Figure 19 shows how to configure the GPIO pins to handle different out-of-limit and fault events.
The Cascade Fault output (CFAULT), is an open-drain, active low output, intended to communicate fault conditions to other ADM1029s in a system, without the intervention of the host processor. The other ADM1029's may then adjust their fans' speed to compensate, depending on the settings of various registers. CFAULT is asserted if any of the following conditions occurs: * A hot-plug event. * Setting Bit 5 of the Configuration Register (address 01h) forces CFAULT to be asserted. * When a GPIO pin is configured as an input by setting Bit 0 of the corresponding GPIO Behavior Register and Bit 2 of the GPIO Behavior Register is also set, CFAULT will be asserted when the logic input is asserted (high or low depending on the polarity bit, Bit 1 of the corresponding GPIO Behavior Register). * If Bit 0 of a Temp. Fault Action Register is set (40h--Local Sensor, 41h--Remote 1, 42h--Remote 2), CFAULT will be asserted if the corresponding temperature high limit is exceeded. * If Bit 4 of a Temp. Fault Action Register is set, CFAULT will be asserted if a temperature input crosses the corresponding temperature low limit, the direction depending on the setting of Bit 3 of the Temp. Fault Action Register. (0 = CFAULT when input goes below low limit, 1 = CFAULT when input goes above low limit). * If Bit 0 of a Fan Fault Action Register (18h or 19h) is set, CFAULT will be asserted when a tach measurement for the corresponding fan exceeds the set limit. * If Bit 0 of a Fan Fault Action Register (18h or 19h) is set, CFAULT will be asserted, when the fan fault input pin for the corresponding fan is asserted (low). * If Bit 0 of an AIN Behavior Register is set (50h--AIN0, 51h--AIN1), CFAULT will be asserted if the corresponding AIN high limit is exceeded. * If Bit 4 of an AIN Behavior Register is set, CFAULT will be asserted if an analog input crosses the corresponding AIN low limit, the direction depending on the setting of Bit 3 of the AIN Behavior Register. (0 = CFAULT when input goes below low limit, 1 = CFAULT when input goes above low limit).
Rev. 1 | Page 27 of 50 | www.onsemi.com
ADM1029
GPIO PINS ENABLE (REG 0x05) ENABLE PINS FOR GPIO FUNCTION (REGISTER 0x05) BIT 0 = 1 BIT 1 = 1 BIT 2 = 1 BIT 3 = 1 BIT 4 = 1 BIT 5 = 1 BIT 6 = 1 BIT 7 PIN 19 CONFIGURED AS GPIO0 PIN 20 CONFIGURED AS GPIO1 PIN 11 CONFIGURED AS GPIO2 PIN 13 CONFIGURED AS GPIO3 PIN 14 CONFIGURED AS GPIO4 PIN 16 CONFIGURED AS GPIO5 PIN 17 CONFIGURED AS GPIO6 RESERVED
CONFIGURE GPIO PINS BEHAVIOR GPIO0 (REG 0x28) | GPIO6 (REG 0x2E)
GPIO PINS BEHAVIOR (REG 0x28 CONFIGURES GPIO0, REG 0x29 CONFIGURES GPIO1, ETC.) BIT 0 BIT 1 BIT 2 = 1 SETS THE DIRECTION FOR GPIO PIN. A '0' CONFIGURES THE PIN AS AN OUTPUT, A '1' SETS THE PIN UP AS AN INPUT SETS THE POLARITY FOR GPIO PIN. A '0' MAKES THE PIN ACTIVE LOW, A '1' MAKES THE PIN ACTIVE HIGH IF GPIO PIN IS CONFIGURED AS AN INPUT, CFAULT IS ASSERTED WHEN GPIO IS ASSERTED. IF GPIO PIN IS CONFIGURED AS AN OUTPUT, GPIO PIN WILL BE ASSERTED IF A HIGH TEMPERATURE LIMIT IS EXCEEDED. THIS CAN BE USED TO SHUT DOWN THE SYSTEM IN AN OVER-TEMPERATURE SITUATION. IF GPIO PIN IS CONFIGURED AS AN INPUT, INT IS ASSERTED WHEN GPIO IS ASSERTED. IF GPIO PIN IS AN OUTPUT, GPIO IS ASSERTED IF A TEMPERATURE LOW LIMIT IS EXCEEDED. IF GPIO PIN IS CONFIGURED AS AN INPUT, FANS GO TO ALARM SPEED IF GPIO IS ASSERTED. IF GPIO PIN IS AN OUTPUT, GPIO IS ASSERTED IF A FAN TACH LIMIT IS EXCEEDED. IF GPIO PIN IS CONFIGURED AS AN INPUT, FANS GO TO HOT-PLUG SPEED IF GPIO IS ASSERTED. IF GPIO PIN IS AN OUTPUT, GPIO IS ASSERTED IF A FAN FAULT IS DETECTED (FAULT PIN). IF GPIO PIN IS AN INPUT, THIS BIT REFLECTS THE STATE OF GPIO PIN. IF GPIO PIN IS AN OUTPUT, GPIO IS ASSERTED IF AN AIN HIGH LIMIT IS EXCEEDED. IF GPIO PIN IS AN INPUT, THIS BIT LATCHES A GPIO ASSERTION EVENT. CLEARED BY WRITING A '0.' IF GPIO PIN IS AN INPUT, GPIO IS ASSERTED IF AN AIN LOW LIMIT IS EXCEEDED.
BIT 3 = 1 CONFIGURE GPIO EVENT MASK GPIO0 (REG 0x38) | GPIO6 (REG 0x3E) BIT 4 = 1 BIT 5 = 1 BIT 6 = 1 BIT 7
BIT 0 = 1
RUN FAN 1 AT ALARM OR HOT-PLUG SPEED IF GPIO PIN IS ASSERTED
IS GPIO PIN ASSERTED?
FAN 1 RUNS AT HOT-PLUG OR ALARM SPEED YES
BIT 1 = 1 BITS 2 - 7
RUN FAN 2 AT ALARM OR HOT-PLUG SPEED IF GPIO PIN IS ASSERTED RESERVED - READ BACK ZERO IS GPIO PIN ASSERTED? FAN 2 RUNS AT HOT-PLUG OR ALARM SPEED YES
GPIO EVENT MASK (CONFIGURE REG 0x38 FOR GPIO0, REG 0x39 FOR GPIO1.....REG 0x3E FOR GPIO6)
Figure 19. Configuring GPIO Pins
Rev. 1 | Page 28 of 50 | www.onsemi.com
ADM1029
Table X. Register Map
Address 00 01 02 03 04 05 06 07 08 09 0B 0C 0D 0E 0F 10 11 18 19 20 21 28 29 2A 2B 2C 2D 2E 30
Name Status Register Config Register Fan Supported By Controller Fans Supported In System GPIOs Supported By Controller GPIO Present/AIN Temp Devices Installed Set Fan x Alarm Speed Set Fan x Hot-Plug Speed Set Fan x Full Speed S/W RESET Fan Spin-Up Manufacturer's ID Major/Minor Revision Manufacturer's Test Register Fan 1 Status Fan 2 Status Fan 1 Fault Action Fan 2 Fault Action Fan 1 Event Mask Fan 2 Event Mask GPIO0 Behavior GPIO1 Behavior GPIO2 Behavior GPIO3 Behavior GPIO4 Behavior GPIO5 Behavior GPIO6 Behavior Local Temperature Offset
Default Value 00h 0000 0000 03h 0000 00?1 7Fh 0????111 0000 0??1 00h 00h 00h 00h 03h 41h 00h 00h 0000 0?0? 0000 0?0? BFh BFh FFh FFh 00h 00h 00h 00h 00h 00h 00h 00h
Description Contains the status of various fault conditions. Configures the operation of the device. Contains the number of fans the device can support. Contains the number of fans actually supported by the device in the application. Contains the number of GPIO pins the device can support. Used to configure GPIO pins as GPIO or as their alternate analog input function. Contains number of temperature sensors installed. Writing to appropriate bit(s) makes fan(s) run at alarm speed. Writing to appropriate bit(s) makes fan(s) run at hot-plug speed. Writing to appropriate bit(s) makes fan(s) run at full speed. Writing A6h to this register causes a software reset. Configures fan spin-up time. This register contains the manufacturer's ID code for the device. Contains the manufacturer's code for major and minor revisions to the device in two nibbles. This register is used by the manufacturer for test purposes. It should not be read from or written to in normal operation. Contains status information for FAN 1. Contains status information for FAN 2. Sets operation of INT, CFAULT, etc., for FAN 1 fault. Sets operation of INT, CFAULT, etc., for FAN 2 fault. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a fault or hot-plug event on FAN 1. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a fault or hot-plug event on FAN 2. Configures the operation of GPIO0. Configures the operation of GPIO1. Configures the operation of GPIO2. Configures the operation of GPIO3. Configures the operation of GPIO4. Configures the operation of GPIO5. Configures the operation of GPIO6. Offset register for local temperature measurement. The value in this register is added to the local temperature value to reduce system offset effects. Offset register for first remote temperature channel (D1). The value in this register is added to the temperature value to reduce system offset effects. Offset register for second remote temperature channel (D2). The value in this register is added to the temperature value to reduce system offset effects. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO0 being asserted. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO1 being asserted. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO2 being asserted. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO3 being asserted.
31
Remote 1 Temperature Offset
00h
32
Remote 2 Temperature Offset
00h
38 39 3A 3B
GPIO0 Event Mask GPIO1 Event Mask GPIO2 Event Mask GPIO3 Event Mask
00h 00h 00h 00h
Rev. 1 | Page 29 of 50 | www.onsemi.com
ADM1029
Table X. Register Map (Continued)
Address 3C 3D 3E 40 41 42 48 49 4A 50 51 58 59 60 61 68 69 70 71 78 79 80
Name GPIO4 Event Mask GPIO5 Event Mask GPIO6 Event Mask Local Temp Fault Action Remote 1 Temp Fault Action Remote 2 Temp Fault Action Local Temp Cooling Action Remote 1 Temp Cooling Action Remote 2 Temp Cooling Action AIN0 Behavior AIN1 Behavior AIN0 Event Mask AIN1 Event Mask Fan 1 Minimum/Alarm Speed Fan 2 Minimum/Alarm Speed Fan 1 Configuration Fan 2 Configuration Fan 1 Tach Value Fan 2 Tach Value Fan 1 Tach High Limit Fan 2 Tach High Limit Local Temp TMIN
Default Value 00h 00h 00h 08h 08h 08h 00h 00h 00h 00h 00h 00h 00h FFh FFh 2Fh 2Fh 00h 00h FFh FFh ??h
Description Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO4 being asserted. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO5 being asserted. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO6 being asserted. Configures the operation of INT, CFAULT, etc. for a Local Temp fault (internal temperature sensor). Configures the operation of INT, CFAULT, etc. for a Remote 1 Temp fault (D1 Temperature Sensor). Configures the operation of INT, CFAULT, etc. for a Remote 2 Temp fault (D2 Temperature Sensor). Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a Local Temp event (internal temperature sensor). Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a Remote 1 Temp event (D1 temperature sensor). Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a Remote 2 Temp event (D2 temperature sensor). Configures the operation of INT, CFAULT, etc. for a fault on Analog Channel 0. Configures the operation of INT, CFAULT, etc. for a fault on Analog Channel 1. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a fault on Channel 0. Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a fault on Channel 1. Contains the Minimum/Alarm speeds for Fan 1. Contains the Minimum/Alarm speeds for Fan 2. Configures hot-plug speed, PWM and tach frequency. Configures hot-plug speed, PWM and tach frequency. Contains the measured value from the FAN 1 tachometer output. Contains the measured value from the FAN 2 tachometer output. Contains the high limit for FAN 1 tachometer measurement. Contains the high limit for FAN 2 tachometer measurement. Defines the starting temperature for the fan when controlled by the local temperature channel, under Automatic Fan Speed Control. Defines the starting temperature for the fan when controlled by the Remote 1 temperature channel, under Automatic Fan Speed Control. (D1 Temp Sensor). Defines the starting temperature for the fan when controlled by the Remote 2 temperature channel, under Automatic Fan Speed Control. (D2 Temp Sensor). This register programs the control range for the local temperature control loop. It also defines the amount of temperature hysteresis applied to the loop. This register programs the control range for the Remote 1 temperature control loop. It also defines the amount of temperature hysteresis applied to the loop.
81
Remote 1 Temp TMIN
??h
82
Remote 2 Temp TMIN
??h
88
Local Temp TRANGE/THYST
51h
89
Remote 1 Temp TRANGE/THYST
51h
Rev. 1 | Page 30 of 50 | www.onsemi.com
ADM1029
Table X. Register Map (Continued)
Address 8A
Name Remote 2 Temp TRANGE/THYST
Default Value 51h
Description This register programs the control range for the Remote 2 temperature control loop. It also defines the amount of temperature hysteresis applied to the loop. High limit for Local measurement (internal sensor). High limit for Remote 1 measurement (D1 Sensor). High limit for Remote 2 measurement (D2 Sensor). Low limit for Local Temp measurement (internal sensor). Low limit for Remote 1 measurement (D1 Sensor). Low limit for Remote 2 measurement (D2 Sensor). Measured value from local temp sensor. Measured value from D1 Remote Sensor. Measured value from D2 Remote Sensor. High limit for measurement on analog Channel 0. High limit for measurement on analog Channel 1. Low limit for measurement on analog Channel 0. Low limit for measurement on analog Channel 1. Measured value of analog Channel 0. Measured value of analog Channel 1.
90 91 92 98 99 9A A0 A1 A2 A8 A9 B0 B1 B8 B9
Local Temp High Limit Remote 1 Temp High Limit Remote 2 Temp High Limit Local Temp Low Limit Remote 1 Temp Low Limit Remote 2 Temp Low Limit Local Temp Value Remote 1 Temp Value Remote 2 Temp Value AIN0 High Limit AIN1 High Limit AIN0 Low Limit AIN1 Low Limit AIN0 Measured Value AIN1 Measured Value
50h (80C) 64h (100C) 64h (100C) 3Ch (60C) 46h (70C) 46h (70C) 00h 00h 00h FFh FFh 00h 00h 00h 00h
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 31 of 50 | www.onsemi.com
ADM1029
CONFIGURATION REGISTERS Register 01h -- Config Register (Power-On Default 000? 000?)
Bit 0 1 2 3
Name Install = ? Global INT mask = 0 ARA Disable = 0 Perform Free-Wheel Test = 0
R/W R/W R/W R/W R/W
Description This bit reflects Bit 1 of Register 0x03 (Fans Supported In System). Setting this bit to 1 will disable the INT output for all interrupt sources. Setting this bit to 1 will disable the SMBus Alert Response Address feature. Setting this bit to 1 will initiate the Fan Free-Wheeling Test. While this test is being performed normal monitoring of fan speeds, temperature and voltages will be temporarily halted. This bit will automatically reset to 0 once the test is complete which will take about 10 seconds. Set to 1 to start round robin monitoring cycle of voltage temperature and fan speeds, fault detection, etc. While this bit is 0, all fans will run at Alarm Speed. This bit is set at power-up; otherwise, if automatic fan speed control is enabled by Pin 18. Setting this bit to 1 forces CFAULT to be asserted (Low). Setting this bit to 1 forces INT to be asserted (Polarity depends on Bit 7). Polarity of INT when asserted. 1 means High and 0 means Low.
4
Start Monitoring = 0
R/W
5 6 7
Force CFAULT = 0 Force INT = 0 INT Polarity = 0
R/W R/W R/W
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Register 05h - GPIO Present / AIN (Power-On Default 0????111)
Bit 0 1 2 3
Name GPIO 0 = 1 GPIO 1 = 1 GPIO 2 = 1 GPIO 3 = ?
R/W R/W R/W R/W R/W
Description Indicates that GPIO0 is being used. Set to 1 on power-up, but can be overwritten by software. Setting this bit to 0 means AIN0 is being used. Indicates that GPIO1 is being used. Set to 1 on power-up, but can be overwritten by software. Setting this bit to 0 means AIN1 is being used. Indicates that GPIO2 is being used. Set to 1 on power-up, but can be overwritten by software. Indicates that GPIO3 is being used. Setting this bit to 0 means TDM1 is being used. The ADM1029 can detect on power-up if TDM1 is connected. If so, this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO4 is being used. Setting this bit to 0 means TDM1 is being used. The ADM1029 can detect on power-up if TDM1 is connected. If so, this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO5 is being used. Setting this bit to 0 means TDM2 is being used. The ADM1029 can detect on power-up if TDM2 is connected. If so, this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO6 is being used. Setting this bit to 0 means TDM2 is being used. The ADM1029 can detect on power-up if TDM2 is connected. If so, this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Unused. Will read back 0.
4
GPIO 4 = ?
R/W
5
GPIO 5 = ?
R/W
6
GPIO 6 = ?
R/W
7
Reserved
R
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 32 of 50 | www.onsemi.com
ADM1029
Register 07h - Set Fan x* Alarm Speed (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 Alarm Speed = 0 Fan 2 Alarm Speed = 0 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description When set to 1, Fan 1 will run at Alarm Speed. When set to 1, Fan 2 will run at Alarm Speed. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTES *"x" denotes the fan number. Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Register 08h - Set Fan x* Hot-Plug Speed (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 Hot-Plug Speed = 0 Fan 2 Hot-Plug Speed = 0 0 0 0 0 0 0
R/W R/W R/W R R R R R R
Description When set to 1, Fan 1 will run at Hot-Plug Speed. When set to 1, Fan 2 will run at Hot-Plug Speed. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTES *"x" denotes the fan number. Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Register 09h - Set Fan x* Full Speed (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 Full Speed = 0 Fan 2 Full Speed = 0 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description When set to 1 Fan 1 will run at Full Speed. When set to 1 Fan 2 will run at Full Speed. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTES *"x" denotes the fan number. Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 33 of 50 | www.onsemi.com
ADM1029
STATUS REGISTERS
Register 00h - Status Register (Power-On Default 00h)
Bit 0 1 2
Name INT CFAULT_in CFAULT_out
R/W R R R
Description This bit is set to 1 when the device is asserting INT low. This bit is the logical OR of several bits in other registers and is cleared when these bits are cleared. This bit is set to 1 when the device is receiving CFAULT low from another device. This bit is set to 1 when the device is asserting CFAULT low. This bit is the logical OR of several bits in other registers and is cleared when these bits are cleared. This bit is set to 1 when either fan is running at Alarm Speed. This bit is the logical OR of several bits in other registers and is cleared when these bits are cleared. This bit is set to 1 when either fan is running at Hot-Plug Speed. This bit is the logical OR of several bits in other registers and is cleared when these bits are cleared. This bit is a logical OR of Bits 1, 3, 6, and 7 in the GPIO Behavior Registers at 28h to 2Eh while they are configured as inputs, and Bit 7 in the AIN Behavior Registers at 50h and 51h. It will be set when any of these bits are set and cleared when all of these bits are cleared. This bit is a logical OR of Bits 1, 3, 6, and 7 in the Fan Status Registers at 10h and 11h. It will be set when any of these bits are set and cleared when all of these bits are cleared. This bit is a logical OR of Bit 7 in the Temp Fault Action Registers at 40h, 41h, and 42h. It will be set when any of these bits are set and cleared when all of these bits are cleared.
3
In Alarm_speed
R
4
In Hot-Plug Speed
R
5
GPIO/AIN Event
R
6
Hot Plug/Fan Fault
R
7
Thermal Event
R
Register 02h - Fan Supported By Controller (Power-On Default 03h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 1 Fan 2 = 1 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R R R R R R R R
Description This bit set to 1 means the ADM1029 can support Fan 1. This bit set to 1 means the ADM1029 can support Fan 2. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
Register 03h - Fans Supported In System (Power-On Default 0000 00?1)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 1 Fan 2 = ? Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description Indicates that Fan 1 is being used. Set to 1 on Power-up, but can be overwritten by software. Indicates that Fan 2 is being used. Set by Pin 18 (TMIN/INSTALL) on Power-up, but can be overwritten by software. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 34 of 50 | www.onsemi.com
ADM1029
Register 04h - GPIOs Supported By Controller (Power-On Default 7Fh)
Bit 0 1 2 3 4 5 6 7
Name GPIO 0 = 1 (Pin 19) GPIO 1 = 1 (Pin 20) GPIO 2 = 1 (Pin 11) GPIO 3 = 1 (Pin 13) GPIO 4 = 1 (Pin 14) GPIO 5 = 1 (Pin 16) GPIO 6 = 1 (Pin 17) Reserved
R/W R R R R R R R R
Description This bit set to 1 means the ADM1029 can support GPIO0, available on Pin 19. This bit set to 1 means the ADM1029 can support GPIO1, available on Pin 20. This bit set to 1 means the ADM1029 can support GPIO2, available on Pin 11. This bit set to 1 means the ADM1029 can support GPIO3, available on Pin 13. This bit set to 1 means the ADM1029 can support GPIO4, available on Pin 14. This bit set to 1 means the ADM1029 can support GPIO5, available on Pin 16. This bit set to 1 means the ADM1029 can support GPIO6, available on Pin 17. Unused. Will read back 0.
Register 06h - Temp Devices Installed (Power-On Default 0000 0??1)
Bit 0 1 2 3 4 5 6 7
Name Local Temp = 1 Remote 1 Temp = ? Remote 2 Temp = ? Reserved Reserved Reserved Reserved Reserved
R/W R R R R R R R R
Description This bit is permanently set to 1 since the local temperature sensor is always available. This bit is set to 1 if the Remote 1 temperature sensor (TDM1) is installed. (Automatically detected on power-up.) This bit is set to 1 if the Remote 2 temperature sensor (TDM2) is installed. (Automatically detected on power-up.) Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 35 of 50 | www.onsemi.com
ADM1029
Register 10h, 11h - Fan x* Status (Power-On Default 0000 0?0?)
Bit 0
Name Missing = x
R/W R
Description Reflects the state of Pins 4/21. Low means Fan x* is installed, High means it is missing. This bit will automatically return Low if a missing fan is replaced. This bit is edge-triggered and latches a Fan x* missing event on removal of Fan x. This bit is cleared by writing a 0 to it. Inverse of Pin 2/23. Low on pin means Fan x* has a fault (Pins 2/23 Low), High on pin means it is OK. This bit will automatically return Low if Pins 2/23 goes high. This bit is edge-triggered and latches a Fan x* fault event on Pins 2/23. This bit is cleared by writing a 0 to it. If the PRESENT pin for a fan input is high (fan not installed) this bit will be cleared automatically. When this bit is set, Fan x* will be stopped and no Fan x* faults will be monitored. If Bit 4 in Fan x* Fault Action Register is set, Fan x* will go to Alarm Speed if an overtemperature event is detected as per settings in the Temp Fault Action Registers. This bit indicates whether Fan x runs at Hot-Plug Speed (bit set to 1) or Alarm Speed (bit set to 0) if both modes are triggered. Latches a Fan x Tach Fault. This bit is cleared by writing a 0 to it. If the PRESENT pin for a fan input is high (fan not installed), this bit will be cleared automatically. This bit is edge-triggered and latches a Fan x Hot-plug event which is the insertion of Fan x. (Note difference to Bit 1.) This bit is cleared by writing a 0 to it. If a fan is Hot-Plug installed, it will run at Normal Speed.
1 2
Missing _L = 0 Fault_ = x
R/W R
3
Fault_L_ = 0
R/W
4
Sleep = 0
R/W
5 6
Hot Plug Priority Tach_Fault_L
R/W R/W
7
Hot_Plug_L
R/W
NOTES *"x" denotes the fan number. Register 10h is for Fan 1 and Register 11h is for Fan 2. Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 36 of 50 | www.onsemi.com
ADM1029
TEMPERATURE REGISTERS
Register 06h - Temp Devices Installed (Power-On Default 0000 0??1)
Bit 0 1 2 3 4 5 6 7
Name Local Temp = 1 Remote 1 Temp = ? Remote 2 Temp = ? Reserved Reserved Reserved Reserved Reserved
R/W R R R R R R R R
Description This bit is permanently set to 1 since the local temperature sensor is always available. This bit is set to 1 if the Remote 1 temperature sensor (TDM1) is installed. (Automatically detected on power-up.) This bit is set to 1 if the Remote 2 temperature sensor (TDM2) is installed. (Automatically detected on power-up.) Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Register 30h, 31h, 32h - Temp x* Offset Registers (Power-On Default 00h)
Bit <7:0>
Name Offset
R/W R/W
Description This register contains an offset value that is automatically added to the temperature value to reduce the effects of systemic offset errors.
*"x" denotes the number of the temperature channel. Register 30h is for Local temperature channel, 31h is for Remote 1 Temp (D1), 32h is for Remote 2 Temp (D2).
Register 40h, 41h, 42h - Temp x* Fault Action (Power-On Default 08h)
Bit 0 1 2 3
Name Assert CFAULT on OT = 0 Alarm speed on OT = 0 INT on OT = 0 Alarm below low = 0
R/W R/W R/W R/W R/W
Description When this bit is set, CFAULT will be asserted when the Temp x* temperature exceeds the Temp x* Temperature High Limit, not otherwise. When this bit is set, the fans(s) will go to alarm speed when the Temp x* temperature exceeds the Temp x* Temperature High limit, not otherwise. When this bit is set, INT will be asserted when the Temp x* temperature exceeds the Temp x* Temperature High Limit, not otherwise. This bit indicates whether an alarm (INT, CFAULT, or Alarm Speed) is asserted when temperature goes above or below the Low Limit. 1 = above, 0 = below. This bit is set to 1 at power-up if automatic fan speed control is enabled by Pin 18, cleared otherwise. When this bit is set, CFAULT will be asserted when the Temp x* temperature crosses the Temp x* Temperature Low Limit, not otherwise. Bit 3 decides whether CFAULT is asserted for going above or below the Low Limit. This bit is set to 1 if Automatic Fan Speed Control is enabled on power-up. When this bit is set, the fans(s) will go to alarm speed when the Temp x* temperature crosses the Temp x* Temperature Low Limit, not otherwise. Bit 3 decides whether Alarm Speed is asserted for going above or below the Low Limit. When this bit is set, INT will be asserted when the Temp x* temperature crosses the Temp x* Temperature Low Limit, not otherwise. Bit 3 decides whether INT is asserted for going above or below the Low Limit. This bit latches a temperature out-of-limit event (i.e., when the temperature goes above the high limit or crosses the low limit) on the Temp x* channel. This bit is cleared by writing a 0 to it.
4
Assert CFAULT on UT = 0
R/W
5
Alarm speed on UT = 0
R/W
6
INT on UT = 0
R/W
7
Latch Temp Fault = 0
R/W
*"x" denotes the number of the temperature channel. Register 40h is for the Local temperature channel, 41h is for Remote 1 Temp (D1), 42h is for Remote 2 Temp (D2).
Rev. 1 | Page 37 of 50 | www.onsemi.com
ADM1029
Register 48h, 49h, 4Ah - Temp x* Cooling Action (Power-On Default 00h)
Bit 0
Name Fan 1 = 0
R/W R/W
Description If a Temp x* out-of-limit event is generated such that fans should be driven at Alarm Speed, Fan 1 will be set to this speed when this bit is set. If no Temp x* out-of-limit event is present, Fan 1 will be set to the speed determined by the automatic fan speed control circuit as a result of temperature measurements on the Temp x* channel when this bit is set. If this bit is not set, Temp x* temperature measurements will have no effect on the speed of Fan 1. If a Temp x* out-of-limit event is generated such that fans should be driven at Alarm Speed, Fan 2 will be set to this speed when this bit is set. If no Temp x* out-of-limit event is present, Fan 2 will be set to the speed determined by the automatic fan speed control circuit as a result of temperature measurements on the Temp x* channel when this bit is set. If this bit is not set, Temp x temperature measurements have no effect on the speed of Fan 2. While in theory it is possible, through setting of Bits 0 and 1 in registers 48h to 4Ah, to have any temperature channel controlling any fan, in practice this is not feasible. A subset of possibilities only are supported as follows: (Bit 0 in 49h set and/or TDM2 controlling Fan 2 Bit 1 in 4Ah set, only) Case 2: Local controlling Fan 1 and/or Fan 2 (Bits 0, 1 in 48h only set) Case 3: TDM1 controlling Fan 1 and/or Fan 2 (Bits 0, 1 in 49h only set) Case 4: TDM2 controlling Fan 1 and/or Fan 2 (Bits 0, 1 in 4Ah only set) Case 5: Fan 1 and/or Fan 2 set to max speed (Bits 0, 1 in 48h, 49h, (Default) determined by temperature 4Ah all set) measurements on all three channels. Other: If Bits 0,1 in registers 48h, 49h, 4Ah are set inconsistent with these cases, fans will run at the speeds determined by the normal speed registers. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Case 1: TDM1 controlling Fan 1
1
Fan 2 = 0
R/W
2 3 4 5 6 7
Reserved Reserved Reserved Reserved Reserved Reserved
R R R R R R
*"x" denotes the number of the temperature channel. Register 48h is for the Local temperature channel. 49h is for Remote 1 Temp (D1), 4Ah is for Remote 2 Temp (D2).
Rev. 1 | Page 38 of 50 | www.onsemi.com
ADM1029
Register 80h, 81h, 82h - Temp x* TMIN (Power-On Default 001??000)
Bit <7:0>
Name Temp x* TMIN
R/W R/W
Description This register contains the minimum temperature value for automatic fan speed control based on the Temp x* temperature. On power-up Pin 18 is sampled by the ADC to determine the default value for Temp x* TMIN. If Pin 18 is strapped to GND or VCC, this register defaults to 32C, but Automatic Fan Speed Control is disabled. There are eight strappable options on Pin 18. These options are used to set Temp x* TMIN and the Install bit in the Config Register (Reg 01h, Bit 0). The options are as follows: ADC MSBs 111 101 110 100 011 010 001 000 R1 0 18 k 22 k 12 k 15 k 47 k 82 k R2 82 k 47 k 15 k 12 k 22 k 18 k 0 Install 1 1 1 1 0 0 0 0 Temp x* TMIN Disabled 48C 40C 32C 32C 40C 48C Disabled
*"x" denotes the number of the temperature channel. Register 80h is for the Local temperature channel, 81h is for Remote 1 Temp (D1), 82h is for Remote 2 Temp (D2).
Register 88h, 89h, 8Ah Temp x* TRANGE/THYST (Power-On Default 51h)
Bit <3:0>
Name Temp x* TRANGE
R/W R/W
Description This nibble contains the temperature range over which automatic fan speed control operates based on the Temp x* measured temperature. Only a limited number of temperature ranges are supported as follows: Bits <3:0> 0000 0001 0010 0011 0100 TRANGE 5C 10C 20C 40C 80C
<7:4>
Temp x* THYST
R/W
This nibble allows programmability of the Hysteresis level around the temperature at which the fan being controlled by Temp x* will switch on in automatic fan speed control mode. Values from 0C to 15C are possible. If a value other than 0C is programmed as a Hysteresis value, the fan will switch on when Temp x* goes above TMIN, but will remain on until Temp x* falls below TMIN -THYST. Between TMIN -THYST and TMIN the fan will run at the programmed minimum pulsewidth in the Fan x* Speed 1 register.
*"x" denotes the number of the temperature channel. Register 88h is for the Local temperature channel , 89h is for Remote 1 Temp (D1), 8Ah is for Remote 2 Temp (D2).
Rev. 1 | Page 39 of 50 | www.onsemi.com
ADM1029
Register 90h, 91h, 92h - Temp x* High Limit (Power-On Default 80 C for Local Sensor, 100 C for Remote Sensors)
Bit <7:0>
Name Temp x* High Limit
R/W R/W
Description This register contains the high limit value for the Temp x* measurement.
*"x" denotes the number of the temperature channel. Register 90h is for the Local temperature channel. 91h is for Remote 1 Temp (D1), 92h is for Remote 2 Temp (D2).
Register 98h, 99h, 9Ah - Temp x* Low Limit (Power-On Default 60 C for Local Sensor, 70 C for Remote Sensors)
Bit <7:0>
Name Temp x* Low Limit
R/W R/W
Description This register contains the low limit value for the Temp x* measurement.
*"x" denotes the number of the temperature channel. Register 98h is for the Local temperature channel. 99h is for Remote 1 Temp (D1), 9Ah is for Remote 2 Temp (D2).
Register A0h, A1h, A2h - Temp x* Measured Value (Power-On Default 00h)
Bit <7:0>
Name Temp x* Value
R/W R
Description This register contains the actual Temp x* measured value.
*"x" denotes the number of the temperature channel. Register A0h is for the Local temperature channel. A1h is for Remote 1 Temp (D1), A2h is for Remote 2 Temp (D2).
Rev. 1 | Page 40 of 50 | www.onsemi.com
ADM1029
FAN REGISTERS
Register 02h - Fan Supported By Controller (Power-On Default 03h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 1 Fan 2 = 1 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R R R R R R R R
Description This bit set to 1 means the ADM1029 can support Fan 1. This bit set to 1 means the ADM1029 can support Fan 2. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
Register 03h - Fans Supported In System (Power-On Default 0000 00?1)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 1 Fan 2 = ? Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description Indicates that Fan 1 is being used. Set to 1 on power-up, but can be overwritten by software. Indicates that Fan 2 is being used. Set by Pin 18 (TMIN/INSTALL) on power-up, but can be overwritten by software. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Register 07h - Set Fan x Alarm Speed (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 Alarm Speed = 0 Fan 2 Alarm Speed = 0 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description When set to 1, Fan 1 will run at Alarm Speed. When set to 1, Fan 2 will run at Alarm Speed. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
Register 08h - Set Fan x Hot-Plug Speed (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 Hot-Plug Speed = 0 Fan 2 Hot-Plug Speed = 0 0 0 0 0 0 0
R/W R/W R/W R R R R R R
Description When set to 1, Fan 1 will run at Hot-Plug Speed. When set to 1, Fan 2 will run at Hot-Plug Speed. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
Rev. 1 | Page 41 of 50 | www.onsemi.com
ADM1029
Register 09h - Set Fan x Full Speed (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 Full Speed = 0 Fan 2 Full Speed = 0 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description When set to 1 Fan 1 will run at Full Speed. When set to 1 Fan 2 will run at Full Speed. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
Register 0Ch - Fan Spin-Up Register (Power-On Default 03h)
Bit <7:4> 3 <2:0>
Name Reserved Spin-up Disable Fan Spin-up Time
R/W R R/W R/W
Description Unused When this bit is set to 1, fan spin-up to full speed will be disabled. These bits select the spin-up time for the fans 000 = 16 seconds 001 = 8 seconds 010 = 4 seconds 011 = 2 seconds (default) 100 = 1 second 101 = 0.25 seconds 110 = 1/16 second 111 = 1/64 second
Register 10h, 11h - Fan x* Status (Power-On Default 0000 0?0?)
Bit 0 1 2
Name Missing = x Missing _L = 0 Fault_ = x
R/W R R/W R
Description Reflects the state of Pins 4/21. Low means Fan x* is installed, High means it is missing. This bit will automatically return Low if a missing fan is replaced. This bit is edge-triggered and latches a Fan x* missing event on removal of Fan x*. This bit is cleared by writing a 0 to it. Inverse of Pin 2/23. Low on pin means Fan x* has a fault (Pins 2/23 Low), High on pin means it is OK. This bit will automatically return Low if Pin 2/23 goes high. This bit is edge-triggered and latches a Fan x* fault event on Pin 2/23. This bit is cleared by writing a 0 to it. If the PRESENT pin for a fan input is high (fan not installed) this bit will be cleared automatically. When this bit is set, Fan x* will be stopped and no Fan x* faults will be monitored. If Bit 4 in Fan x* Fault Action Register is set then Fan x* will go to Alarm Speed if an overtemperature event is detected as per settings in the Temp Fault Action Registers. This bit indicates whether Fan x* runs at Hot-Plug Speed (bit set to 1) or Alarm Speed (bit set to 0) if both modes are triggered. Latches a Fan x* Tach fault. This bit is cleared by writing a 0 to it. If the PRESENT pin for a fan input is high (fan not installed) this bit will be cleared automatically. This bit is edge-triggered and latches a Fan x* Hot-Plug event which is the insertion of Fan x*. (Note difference to Bit 1) This bit is cleared by writing a 0 to it. If a fan is Hot-Plug installed, it will run at Normal Speed.
3
Fault_L_ = 0
R/W
4
Sleep = 0
R/W
5 6
Hot Plug Priority Tach_Fault_L
R/W R/W
7
Hot_Plug_L
R/W
NOTES *"x" denotes the fan number. Register 10h is for Fan 1 and Register 11h is for Fan 2. Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 42 of 50 | www.onsemi.com
ADM1029
Register 18h, 19h - Fan x* Fault Action (Power-On Default BFh)
Bit 0 1 2 3 4
Name Assert CFAULT on Fault = 1 Assert INT on Fault = 1 Assert CFAULT on Hot Unplug = 1 Assert INT on Hot Unplug = 1 Thermal Override in Sleep = 1 Drive Fault_ on Fault_L = 1 Hot-Plug Speed on CFAULT in = 0 Alarm on CFAULT = 1
R/W R/W R/W R/W R/W R/W
Description If this bit is set, CFAULT will be asserted when there is a fault (Tach or Pins 2/23) on Fan x*. If this bit is set, INT will be asserted when there is a fault (Tach or Pins 2 23) on Fan x*. If this bit is set, CFAULT will be asserted when there is a hot unplug event on Fan x*. If this bit is set, INT will be asserted when there is a hot unplug event on Fan x*. If Bit 4 in Fan x* Status Register is set then Fan x* will go to Alarm Speed if an overtemperature event is detected as per settings in Temp x* Fault Action Registers, while this bit is set. If Bit 3 or Bit 6 of Reg 10 is set, drive Pins 2, 23 low if a fault is generated. When this bit is set, Fan x* will go to Hot-Plug Speed when CFAULT is pulled low externally. When this bit is set, Fan x* will go to Alarm Speed when CFAULT is pulled low externally.
5 6 7
R/W R/W R/W
*"x" denotes the fan number. Register 18h is for Fan 1 and Register 19h is for Fan 2.
Register 20h, 21h - Fan x* Event Mask (Power-On Default FFh)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 1 Fan 2 = 1 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description If a fault (Tach or Pins 2/23) is detected on Fan x*, Fan 1 will be driven to Alarm Speed when this bit is set. If a fault (Tach or Pins 2/23) is detected on Fan x*, Fan 2 will be driven to Alarm Speed when this bit is set. Unused. Will read back 1. Unused. Will read back 1. Unused. Will read back 1. Unused. Will read back 1. Unused. Will read back 1. Unused. Will read back 1.
*"x" denotes the fan number. Register 20h is for Fan 1 and Register 21h is for Fan 2.
Register 60h, 61h - Fan x* Minimum/Alarm Speed (Power-On Default FFh)
Bit 3-0
Name Fan x Minimum Speed
R/W R/W
Description This nibble contains the Normal speed value for Fan x*. When in automatic fan this nibble will contain the minimum speed at which Fan x* will run. The power-up default for the Min Speed should be 5hex which corresponds to 33% PWM duty cycle. This nibble contains the Alarm speed value for Fan x*.
7-4
Fan x Alarm Speed
R/W
*"x" denotes the fan number. Register 60h is for FAN 1 and 61h is for FAN 2.
Rev. 1 | Page 43 of 50 | www.onsemi.com
ADM1029
Register 68h, 69h - Fan x* Configuration (Power-On Default 2Fh)
Bit <3:0>
Name Fan x* Hot-Plug Speed
R/W R/W
Description This nibble contains the Hot-Plug speed value for Fan x*. This is the speed the other fan(s) runs at if Fan x* is Hot-Plug removed. If a fan is Hot-Plug installed, it will run at Normal Speed. These bits allow programmability of the Nominal PWM Frequency for Fan x*. The following options are supported: Bits 5-4 PWM Freq 00 15.625 Hz 01 62.5 Hz 10 250 Hz - Default 11 1000 Hz These bits contain the oscillator frequency for the Fan x* tach measurement. If set to 00, tach measurement is disabled for Fan x*. Bit 7 Bit 6 Oscillator Frequency (Hz) 0 0 Measurement disabled 0 1 470 1 0 940 1 1 1880
<5:4>
PWM Frequency
R/W
<7:6>
Oscillator Frequency
R/W
*"x" denotes the fan number. Register 68h is for FAN 1 and 69h is for FAN 2.
Register 70h, 71h - Fan x* Tach Value (Power-On Default 00h)
Bit <7:0>
Name Fan x* Tach Value
R/W R
Description This register contains the value of the Fan x* tachometer measurement.
*"x" denotes the fan number. Register 70h is for FAN 1 and 71h is for FAN 2.
Register 78h, 79h - Fan x* Tach High Limit (Power-On Default FFh)
Bit <7:0>
Name Fan x* Tach High Limit
R/W R/W
Description This register contains the limit value for the Fan x* tachometer measurement. Since the tachometer circuit counts between tach pulses, a slow fan will result in a larger measured value, so exceeding the limit is the way to detect a slow or stopped fan.
*"x" denotes the fan number. Register 78h is for FAN 1 and 79h is for FAN 2.
Rev. 1 | Page 44 of 50 | www.onsemi.com
ADM1029
GPIO REGISTERS
Register 04h-GPIOs Supported by Controller (Power-On Default 7Fh)
Bit 0 1 2 3 4 5 6 7
Name GPIO 0 = 1 (Pin 19) GPIO 1 = 1 (Pin 20) GPIO 2 = 1 (Pin 11) GPIO 3 = 1 (Pin 13) GPIO 4 = 1 (Pin 14) GPIO 5 = 1 (Pin 16) GPIO 6 = 1 (Pin 17) Reserved
R/W R R R R R R R R
Description This bit set to 1 means the ADM1029 can support GPIO0, available on Pin 19. This bit set to 1 means the ADM1029 can support GPIO1, available on Pin 20. This bit set to 1 means the ADM1029 can support GPIO2, available on Pin 11. This bit set to 1 means the ADM1029 can support GPIO3, available on Pin 13. This bit set to 1 means the ADM1029 can support GPIO4, available on Pin 14. This bit set to 1 means the ADM1029 can support GPIO5, available on Pin 16. This bit set to 1 means the ADM1029 can support GPIO6, available on Pin 17. Unused. Will read back 0.
Register 05h-GPIO Present/AIN (Power-On Default 0????111)
Bit 0 1 2 3
Name GPIO 0 = 1 GPIO 1 = 1 GPIO 2 = 1 GPIO 3 = ?
R/W R/W R/W R/W R/W
Description Indicates that GPIO0 is being used. Set to 1 on power-up, but can be overwritten by software. Setting this bit to 0 means AIN0 is being used. Indicates that GPIO1 is being used. Set to 1 on power-up, but can be overwritten by software. Setting this bit to 0 means AIN1 is being used. Indicates that GPIO2 is being used. Set to 1 on power-up, but can be overwritten by software. Indicates that GPIO3 is being used. Setting this bit to 0 means TDM1 is being used. The ADM1029 can detect on power-up if TDM1 is connected. If so then this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO4 is being used. Setting this bit to 0 means TDM1 is being used. The ADM1029 can detect on power-up if TDM1 is connected. If so then this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO5 is being used. Setting this bit to 0 means TDM2 is being used. The ADM1029 can detect on power-up if TDM2 is connected. If so then this bit is set to 0, otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO6 is being used. Setting this bit to 0 means TDM2 is being used. The ADM1029 can detect on power-up if TDM2 is connected. If so then it is set to 1. The default setting can be overwritten by software. Unused. Will read back 0.
4
GPIO 4 = ?
R/W
5
GPIO 5 = ?
R/W
6
GPIO 6 = ?
R/W
7
Reserved
R
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Rev. 1 | Page 45 of 50 | www.onsemi.com
ADM1029
Register 28h, 29h, 2Ah, 2Bh, 2Ch, 2Dh, 2Eh - GPIOx* Behavior (Power-On Default 00h)
Bit 0 1 2
Name Direction = 0 Polarity = 0 Bit 2 = 0
R/W R/W R/W R/W
Description This bit indicates the direction for GPIOx* pin. When set to 1 GPIOx* will function as an input, when 0 GPIOx* will function as an output. This bit indicates the polarity of the GPIOx* pin. When set to 1 GPIOx* will be active high, when 0 GPIOx* will be active low. If GPIOx* is configured as an input, CFAULT will be asserted if GPIOx* pin is asserted while this bit is set. If GPIO2 is configured as an output, GPIO2 will be asserted if a temperature High limit is exceeded while this bit is set. If automatic fan speed control is enabled, this bit will be set by default. This can be used as a SHUTDOWN signal for a catastrophic overtemperature event. If GPIOx* is configured as an input, INT will be asserted if GPIOx* pin is asserted while this bit is set. If GPIOx* is configured as an output, GPIOx* will be asserted if a temperature Low limit is exceeded while this bit is set. If GPIOx* is configured as an input, Fans will go to Alarm Speed if GPIOx* pin is asserted while this bit is set. If GPIOx* is configured as an output, GPIOx* will be asserted if a Fan Tach limit is exceeded while this bit is set. If GPIOx* is configured as an input, Fans will go to Hot-Plug Speed if GPIOx* pin is asserted while this bit is set. If GPIOx* is configured as an output, GPIOx* will be asserted if a Fan Fault (Pins 2/23) is detected while this bit is set. If GPIOx* is configured as an input, this bit will reflect state of GPIOx* pin. If GPIOx* is configured as an output, GPIOx will be asserted if an AIN high limit is exceeded while this bit is set. If GPIOx* is configured as an input, this bit will latch a GPIOx* assertion event. This bit is cleared by writing a 0 to it. If GPIOx* is configured as an output, GPIOx* will be asserted if an AIN Low limit is exceeded while this bit is set.
3
Bit 3 = 0
R/W
4
Bit 4 = 0
R/W
5
Bit 5 = 0
R/W
6
Bit 6 = 0
R R/W R/W
7
Bit 7 = 0
*"x" denotes the number of the GPIO pin. Register 28h controls GPIO0, 29h controls GPIO1, etc.
Register 38h, 39h, 3Ah, 3Bh, 3Ch, 3Dh, 3Eh - GPIOx* Event Mask (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 0 Fan 2 = 0 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R R R R R R
Description If GPIOx* is asserted such that fans should be driven at Alarm or Hot-Plug Speed, Fan 1 will be set to this speed when this bit is set. If GPIOx* is asserted such that fans should be driven at Alarm or Hot-Plug Speed, Fan 2 will be set to this speed when this bit is set. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0. Unused. Will read back 0.
*"x" denotes the number of the GPIO pin. Register 38h is for GPIO0, 39h is for GPIO1 etc.
Rev. 1 | Page 46 of 50 | www.onsemi.com
ADM1029
AIN REGISTERS
Register 05h - GPIO Present/AIN (Power-On Default 0????111)
Bit 0 1 2 3
Name GPIO 0 = 1 GPIO 1 = 1 GPIO 2 = 1 GPIO 3 = ?
R/W R/W R/W R/W R/W
Description Indicates that GPIO0 is being used. Set to 1 on power-up, but can be overwritten by software. Setting this bit to 0 means AIN0 is being used. Indicates that GPIO1 is being used. Set to 1 on Power-up, but can be overwritten by software. Setting this bit to 0 means AIN1 is being used. Indicates that GPIO2 is being used. Set to 1 on power-up, but can be overwritten by software. Indicates that GPIO3 is being used. Setting this bit to 0 means TDM1 is being used. The ADM1029 can detect on power-up if TDM1 is connected. If so, this bit is set to 0; otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO4 is being used. Setting this bit to 0 means TDM1 is being used. The ADM1029 can detect on power-up if TDM1 is connected. If so, this bit is set to 0; otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO5 is being used. Setting this bit to 0 means TDM2 is being used. The ADM1029 can detect on power-up if TDM2 is connected. If so, this bit is set to 0; otherwise it is set to 1. The default setting can be overwritten by software. Indicates that GPIO6 is being used. Setting this bit to 0 means TDM2 is being used. The ADM1029 can detect on power-up if TDM2 is connected. If so, this bit is set to 0; otherwise it is set to 1. The default setting can be overwritten by software. Unused. Will read back 0.
4
GPIO 4 = ?
R/W
5
GPIO 5 = ?
R/W
6
GPIO 6 = ?
R/W
7
Reserved
R
NOTE Question marks on this and following pages indicate bit settings that depend on the state of certain pins on power-up.
Register 50h, 51h - AINx* Behavior (Power-On Default 00h)
Bit 0 1 2 3 4
Name Assert CFAULT on HI_LIM = 0 Alarm speed on HI_LIM = 0 INT on HI_LIM = 0 Alarm below low = 0 Assert CFAULT on LO_LIM = 0 Alarm speed on LO_LIM = 0 INT on LO_LIM = 0 Latch AIN Fault = 0
R/W R/W R/W R/W R/W R/W
Description When this bit is set, CFAULT is asserted when AINx* exceeds the AINx* high limit. When this bit is set, the fans go to alarm speed when AINx* exceeds the AINx* high limit. When this bit is set, INT is asserted when AINx* exceeds the AINx* high limit. This bit indicates whether an alarm (INT, CFAULT or Alarm Speed) is asserted when AINx* goes above or below the Low Limit. 1 = above. 0 = below. When this bit is set, CFAULT is asserted when AINx* crosses the AINx* low limit. Bit 3 decides whether CFAULT is asserted for going above or below the Low Limit. When this bit is set, the fans go to alarm speed when AINx* crosses the AINx* low limit. Bit 3 decides whether Alarm Speed is asserted for going above or below the Low Limit. When this bit is set, INT is asserted when AINx* crosses the AINx* low limit. Bit 3 decides whether INT is asserted for going above or below the Low Limit. This bit latches an out-of-limit event (i.e., when AINx* goes above the high limit or crosses the low limit) on the AINx* channel. This bit is cleared by writing a 0 to it.
5
R/W
6 7
R/W R/W
*"x" denotes the number of the AIN channel. Register 50h controls AIN0 and 51h controls AIN1.
Rev. 1 | Page 47 of 50 | www.onsemi.com
ADM1029
Register 58h, 59h - AINx* Event Mask (Power-On Default 00h)
Bit 0 1 2 3 4 5 6 7
Name Fan 1 = 0 Fan 2 = 0 Reserved Reserved Reserved Reserved Reserved Reserved
R/W R/W R/W R/W R/W R/W R/W R/W R/W
Description If an AINx* out-of-limit event is generated such that fans should be driven at Alarm Speed, Fan 1 will be set to this speed when this bit is set. If an AINx* out-of-limit event is generated such that fans should be driven at Alarm Speed, Fan 2 will be set to this speed when this bit is set. Undefined Undefined Undefined Undefined Undefined Undefined
*"x" denotes the number of the AIN channel. Register 58h is for AIN0 and 59h is for AIN1.
Register A8h, A9h - AINx* High Limit (Power-On Default FFh)
Bit <7:0>
Name AINx* High Limit
R/W R/W
Description This register contains the high limit value for the AINx* analog input channel.
*"x" denotes the number of the AIN channel. Register A8h is for AIN0 and A9h is for AIN1.
Register B0h, B1h - AINx* Low Limit (Power-On Default 00h)
Bit <7:0>
Name AINx* Low Limit
R/W R/W
Description This register contains the low limit value for the AINx* analog input channel.
*"x" denotes the number of the AIN channel. Register B0h is for AIN0 and B1h is for AIN1.
Register B8h, B9h - AINx* Measured Value (Power-On Default 00h)
Bit <7:0>
Name AINx* value
R/W R
Description This register contains the measured value of the AINx* analog input channel.
*"x" denotes the number of the AIN channel. Register B8h is for AIN0 and B9h is for AIN1.
Rev. 1 | Page 48 of 50 | www.onsemi.com
ADM1029
MISCELLANEOUS REGISTERS
Register 0Bh - S/W RESET (Power-On Default 00h)
Bit <7:0>
Name S/W Reset
R/W R/W
Description Writing A6 hex to this register location causes a software reset identical to a power-on reset. This register is self-clearing so reading from it after the software reset has completed will result in 00 hex being read.
Register 0Dh - Manufacturer's ID (Power-On Default 41h)
Bit <7:0>
Name Manufacturer's ID Code
R/W R
Description This register contains the manufacturer's ID code for the device.
Register 0Eh - Revision (Power-On Default 00h)
Bit <3:0> <7:4>
Name Minor Revision Code Major Revision Code
R/W R R
Description This nibble contains the manufacturer's code for minor revisions to the device. This nibble contains the manufacturer's code for major revisions to the device which would likely require a S/W revision.
Register 0Fh - Manufacturer's Test Register (Power-On Default 00h)
Bit <7:0>
Name Manufacturer's Test
R/W R/W
Description This register is used by the manufacturer for test purposes. It should not be read from or written to in normal operation.
ORDERING GUIDE
Model ADM1029ARQZ
1
Temperature Range
1
Package Description Shrink Small Outline Package (QSOP) Shrink Small Outline Package (QSOP)
Package Option RQ-24 RQ-24
0C to 100C 0C to 100C
ADM1029ARQZ-R71
Z = Pb-Free part
Rev. 1 | Page 49 of 50 | www.onsemi.com
ADM1029
QSOP24 NB CASE 492Bi01 ISSUE A DATE 06 MAY 2008
2X
SCALE 2:1 D A
24 13
0.20 C D D C
GAUGE PLANE
L2
E1
2X
E
L DETAIL A
2X 12 TIPS
C
NOTES: 1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M, 1994. 2. CONTROLLING DIMENSION: MILLIMETERS. 3. DIMENSION b DOES NOT INCLUDE DAMBAR PROTRUSION. 4. DIMENSION D DOES NOT INCLUDE MOLD FLASH, PROTRUSIONS, OR GATE BURRS. MOLD FLASH, PROTRUSIONS, OR GATE BURRS SHALL NOT EXCEED 0.15 PER SIDE. DIMENSION E1 DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSION. INTERLEAD FLASH OR PROTRUSION SHALL NOT EXCEED 0.15 PER SIDE. D AND E1 ARE DETERMINED AT DATUM H. 5. DATUMS A AND B ARE DETERMINED AT DATUM H. DIM A A1 b C D E E1 e h L L2 M MILLIMETERS MIN MAX 1.35 1.75 0.10 0.25 0.20 0.30 0.19 0.25 8.65 BSC 6.00 BSC 3.90 BSC 0.635 BSC 0.22 0.50 0.40 1.27 0.25 BSC 0_ 8_
0.20 C D
1 12 24X
0.25 C D b 0.25
M
e 0.10 C
B
C A-B D A H
h x 45 _
0.10 C
24X
A1
C
SEATING PLANE
DETAIL A
M
SOLDERING FOOTPRINT
24X
0.42 24 13
24X
1.12
GENERIC MARKING DIAGRAM*
xxxxxxxxx AWLYWW
6.40
xxx A WL Y WW
= Specific Device Code = Assembly Location = Wafer Lot = Year = Work Week
1 0.635 PITCH
12
DIMENSIONS: MILLIMETERS
*This information is generic. Please refer to device data sheet for actual part marking. PbiFree indicator, "G", may or not be present.
ON Semiconductor and the ON logo are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. "Typical" parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including "Typicals" must be validated for each customer application by customer's technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada Email: orderlit@onsemi.com N. American Technical Support: 800-282-9855 Toll Free USA/Canada. Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81-3-5773-3850 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative
Rev. 1 | Page 50 of 50 | www.onsemi.com


▲Up To Search▲   

 
Price & Availability of ADM1029ARQZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X